744651
13
Zoom out
Zoom in
Previous page
1/28
Next page
|13
12
EN
Prior to set up
Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up.
Note
No modifications may be made to the firing installation. This also
leads to loss of warranty and guarantee.
Floor protection
A glass, sheet steel or ceramic plate is recommended, if the floor is
combustible (wood, carpet, etc.). Please observe the respective local
regulations and rules.
Flue pipe connection
QFlue pipes pose a particular source of hazard regarding gas leaks
and fire. Get the advice of an authorised specialist company for
the layout and assembly.
QPlease observe the corresponding installation guidelines for walls
panelled with wood when connecting your flue pipes to the stove.
QObserve the formation of flue gas (atmospheric inversion) and
draughts when the weather is unfavourable.
QInfeed of too little combustion air can lead to smoke in the rooms
or to flue gas leaks. Hazardous deposits in the stove and chimney
may also occur.
QIf flue gas escapes, let the fire burn out and check whether all the
air inlet openings are free and the flue gas pipes and the stove
pipe are clean. If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney.
The correct chimney connection
There are several ways to connect your stove to the chimney, eg:
*1
*2
*3
*1
*2
*3
1) wind break, 2) chimney, 3) inspection opening
For the selection of the connection and to ensure a proper connection
between the stove and chimney, please read the guide „INSTALLING
THE STOVE“ or ask your local chimney sweep.
Stoves type 1 (BA 1):
QSuitable for multiple occupancy. (Note the different country
regulations.)
QThese may only be operated with the combustion chamber door
closed.
QThe combustion chamber door is to be kept closed when the
stove is not in operation.
QFouling of the chimney i.e. deposits of highly inflammable materials
such as soot and tar and subsequently fire in the chimney may
occur if the chimney is miscalculated and dimensioned wrong.
QIf this occurs, disconnect the mains plug. Phone the fire brigade
and get yourself and other residents out of harm’s way.
Note
Your pellet stove has been tested as a room-air independent stove
according to EN14785. It can be operated room air dependent or
room air independent.
ROOM-AIR INDEPENDENT OPERATION:
The stove is certificated for type FC52x / FC62x of the approval
principles for the inspection and evaluation of ambient air
independent fireplaces specified by the Deutsches Institut für
Bautechnik (DIBT) (German Institute for Building Technology).
Thanks to an air-tight configuration of the air supply line and flue
pipes the stove may be operated in air-tight rooms and in rooms
with room-air installations (e.g. controlled ventilation and venting
systems, extractors etc.).
ROOM-AIR DEPENDENT OPERATION:
In combination with room-air installations (e.g. controlled
ventilation and venting systems (extractors etc.) it must
be ensured that the stove and the room air system are
monitored and safeguarded mutually (e.g. via a differential
pressure controller). The combustion air infeed of approx.
20 m3/h must be ensured.
Please observe the respective local regulations and rules in
consultation with your master chimney sweep. For changes after
the printing of this manual, we can not assume any liability. We
reserve the right to change without notice.
Convection air conduction
Only for stoves with MultiAir
The stove is delivered with a cover on the convection air outlet to
prevent direct heat to the wall.
Operation without this cover or without attached convection pipes is
not allowed. If you do though no warranty and no liability is accepted
for damage.
QThe amount of air and temperature is designed to heat one
additional room.
QNote the regional specific fire safety regulations and clarify the
connection situation with the competent authority
QThe max. temperature of the convection air is 180° C at the air
outlet.
QThe convection air should be as short as possible.
QKeep the number of deflections as small as possible.
Note
Please pay attention to the national and country-specific building
and fire regulations when connecting the convection air pipes.
Installation and assembly must be performed by a trained
specialist only.
example
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Sono RAO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Sono RAO in the language / languages: English as an attachment in your email.

The manual is 13,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Sono RAO

Rika Sono RAO Installation Guide - English - 48 pages

Rika Sono RAO User Manual - German - 28 pages

Rika Sono RAO Installation Guide - German, Dutch - 48 pages

Rika Sono RAO User Manual - Dutch - 28 pages

Rika Sono RAO Installation Guide - French, Italian - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info