745525
20
Zoom out
Zoom in
Previous page
1/24
Next page
20
10. PROBLEMS - POSSIBLE SOLUTIONS
Problem 1
Fire burns with weak, orange flame. Pellets heap up in fire trough, window
soots up.
Cause(s)
QInsufficient combustion air
QPoor chimney draught
QStove is sooted over inside
Possible solutions
QRemove any ash or clinker from the fire trough that may block the air inlets.
(see CLEANING and MAINTENANCE)
QIf possible swap to better pellet quality.
QCheck whether flue gas pipes are blocked with ash (see CLEANING and
MAINTENANCE).
QCheck whether the air intake or flue tubes are blocked.
QCheck door and cleaning cover seals for leaks (see CLEANING and
MAINTENANCE)
QClean fan (see CLEANING and MAINTENANCE)
QHave service performed by authorised specialist company.
QThe window has to be cleaned from time to time (see CLEANING and
MAINTENANCE)
Problem 2
Stove smells strongly and smokes outside.
Cause(s)
QBurning-in phase (taking into service)
QStove has accumulated dust and/or dirt
Possible solutions
QWait to end of burning-in phase and ventthe room sufficiently.
QVacuum off any dust deposits from the convection air openings at regular
intervals
Problem 3
Flue gas discharge when wood is added and during heating phase.
Cause(s)
QLeaking cleaning openings
QChimney draught too low
QLeaking flue pipe connection
Possible solutions
QCheck seals and replace (fire door, cleaning lid, ..)
QCheck chimney
QCheck connections and if necessary re-seal
Note
Please note that checks on the control system and wiring may only be
performed in unit switched dead. Any repairs may only be performed by
trained specialists.
Tip
If a malfunction message occurs, the cause must first be remedied; the
unit can be put back into operation by acknowledging the malfunction at the
internal unit.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Roco Multiair at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Roco Multiair in the language / languages: English as an attachment in your email.

The manual is 11,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Roco Multiair

Rika Roco Multiair User Manual - German - 24 pages

Rika Roco Multiair User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info