Installation- and Operating Instruction Cooker Hoods
fi200909
8
G
B
11.6 Mounting the extractor hood
See chapter “General installation instructions” or
where applicable the separately supplied mounting
instructions.
12. Exhaust air pipeline
(The exhaust air hose is not included in the
scope of supply)
Fig. B air outlet to outdoors
Fig. A air outlet via an air shaft
The exhaust air line should be as short and
straight as possible.
To avoid excessive noise or a reduced extraction
capacity the diameter of the exhaust air pipeline
should not be less than 120 mm.
Use or form only large radius bends. Small radius
bends reduce the extraction capacity of the hood.
Use only smooth pipelines or flexible hoses of
non-flammable materials for the exhaust air
pipeline
If the exhaust air pipeline is horizontally routed,
there must be a minimum gradient of 1 cm per
metre or an inclination angle of 2°. (Fig. C)
Otherwise condensation water could run into the
extractor hood motor.
If the exhaust air is directed into an exhaust air
duct, the end of the entry fitting must be directed
in the direction of flow.
If the exhaust air pipeline is routed though cool
rooms, lofts etc. there can be a large temperature
drop within the individual parts of the pipeline,
resulting in sweating or condensation water
production. This renders outlet pipeline insulation
necessary.
In some cases a condensation water barrier must
be installed in addition to adequate insulation
(these are available from leading building material
suppliers).
13. Guaranty
Please take note of the general Guaranty terms and the
Guaranty period, stated in the attached Guaranty card.
If the appliance documentation does not include a
Guaranty card, please contact your dealer.
There is no Guaranty on light fittings.
The manufacturer is not responsible for any
faults occurring through non-compliance with the
above information and provisions.
The manufacturer is constantly engaged in the
further improvement of his products. Please note
that products are subject to changes in form,
equipment and the applied technology.
C
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Respekta CH 77090WA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Respekta CH 77090WA in the language / languages: English, German as an attachment in your email.

The manual is 1.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info