5)
Temperature
setting
of
refrigerating
chamber
Press
temperatureadjusting
button
ofthe
refrigerating
chamber
[I
REF-TEl\/IF,’-
refrigerating
chamber
region
will
make
flashing
indication.
Then
press
the
button
:|
REF.TEMP.
again
to
set
the
temperature,
and
will
hear
one
beep.
Setting
scope
is
between
2°C
and
8°C.Every
time
you
press
the
button,
the
temperature
will
change
1°C.
After
adjusting,the
digital
tube
will
keep
flashing
for
5
seconds.
New
temperature
setting
will
come
into
effect
after
locking.
.
6)
Temperature
setting
of
freezing
chamber
Press
temperature
adjusting
button
ofthe
fr
ezing
chamber
[I
FRZ-TEMP-,
freezing
chamber
region
will
make
flashing
indication.
Then
press
the button
Ii
FRZ.TEM
P-again
to
set
the
temperature,
and
you
will
hear
one
beep.
Setting
scope
is
between
-16°C
and
-24°C.
Every
timeyou
press
the
button,
the
temperature
will
change
1°C.
After
adjusting,
the
digital
tube
will
keep
flashing
for
5
seconds.
New
temperature
setting
will
come
into
effect
after
locking.
Recommended
setting:
Refrigerated
chamber4
°C,
freezing
chamber
-
18
°C.
7
)
Storage
upon
power failure
ln
case
of
power
failure,
the
instant
working
state
will
be
locked
and
maintained
till
re-electrification.
8
)
Opening
warning
and
alarm
control
When
the
refrigerator
doors
get
open,
the
opening
music
will
play.
if
the
door
is
not
closed
in
two
minutes,
the
buzzer
will
sound
once
every
second
till
the
door
is
closed.
Press
any
button
to
stop
the
buzzer
alarm.
9
)
Fault
indication
The
following
warnings
appearing
on
the
display
indicate
corresponding
faults
of
the
refrigerator.
Though
the
refrigerator
may
still
have
cold
storage
function
with
the
following
faults,
the
user
shall
contact
a
maintenance
specialist
for
maintenance,
so
as
to
ensure
optimized
operation
of
the
appliance.
Fault
Code
Fault
Description
Temperature
sensor
failure
E1
of
refrigerating
chamber
.
Temperature
sensor
failure
of
freezing
chamber
E2
E5
Freezing
defrost
sensor
detection
circuit
error
E6
Communication
error
Ambient
temperature
sensor
error
E7
12
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Respekta AC179IX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Respekta AC179IX in the language / languages: English, German as an attachment in your email.

The manual is 9.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info