Filament Settings
(1) Filament diameter and filament diameter tolerances according to the manufacturer specification are set here. If no
manufacturer’s
specification is present, these values can also be measured with a calliper (measure 1 m of filament material
in 10 dierent points and then set the average here).
(2) Temperature settings for extruder and heating bed separated by first and all other layers.
Observe the settings recommended by the filament manufacturer!
Since the best values may fluctuate extremely depending on the filament manufacturer, perform your own tests based on
the pre-settings to achieve the best printing quality. When performing the tests, proceed in 5 °C steps and compare the
results during or after printing with other settings. The first layer should always be printed a little more hotly for better
adhesion on the heating plate.
(1) Here you can choose between automatic cooling and permanent operation of the fan at the extruder.
(2) Setting
of the fan speed.
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Renkforce RF1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Renkforce RF1000 in the language / languages: English as an attachment in your email.

The manual is 8,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Renkforce RF1000

Renkforce RF1000 User Manual - German - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info