585218
6
Zoom out
Zoom in
Previous page
1/9
Next page
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
Example for the heating mode
If the room thermostat serves a frost monitor and should keep the room temperature
of e.g. a storage room or cellar above +5 °C, connect the front outlet of the room
thermostat to a heater, such as a convector.
Turn off the room thermostat and check which operating mode is currently installed
(“
“ = Heating mode, “ “ = Cooling mode).
Choose Heating mode as the operating mode.
Switch on the room thermostat. The control-LED (1) must now light up (LED is red =
the front outlet is deactivated, LED is green = the front outlet is activated).
Set a temperature limit of +5 °C with the buttons “F“ (7) and “S“ (8). The room ther-
mostat is therefore ready for operation.
If the room temperature falls under +5 °C for longer than 1 minute, the room ther-
mostat will turn on the connected heater. The control-LED (1) lights up green, and
additionally the symbol “
“ appears.
The time period of 1 minute serves to prevent the connected heater from
being switched on or off in succession too quickly.
If the room temperature rises higher than +5 °C, the room thermostat turns off the
connected heater again. The control-LED (1) lights up red, and the symbol “
“ dis-
appears again.
Example for the cooling mode
If the room thermostat is to keep a room from excessively high temperatures, con-
nect the front outlet of the room thermostat to a ventilator for example (or a suitable
air conditioner).
Turn off the room thermostat and check which operating mode is currently installed
(“
“ = Heating mode, “ “ = Cooling mode).
Choose Cooling mode as the operating mode.
Switch on the room thermostat. The control-LED (1) must now light up (LED is red =
the front outlet is deactivated, LED is green = the front outlet is activated).
Set a temperature limit of +25 °C with the buttons F(7) and S(8). The room
thermostat is therefore ready for operation.
If the room temperature rises over +25 °C for longer than 3 minutes, the room ther-
mostat will turn on the connected ventilator (or an air conditioner). The control-
LED (1) lights up green, and additionally the symbol “
“ appears.
The time period of 3 minutes serves to prevent the connected air conditioner
from being switched on or off in succession too quickly.
If the room temperature falls below +25 °C, the room thermostat will turn the con-
nected ventilator (or a air conditioner) off again. The control-LED (1) lights up red,
and the symbol “
“ disappears again.
Maintenance and care
The product does not require maintenance. The product contains no parts that re-
quire servicing. Therefore, do not open/dismantle it. Maintenance or repair may only
be performed by qualified personnel or a specialised repair shop.
Before cleaning, disconnect the room thermostat from the power supply. To do this,
pull it completely out of the mains socket. Then disconnect the room thermostat
from the connected device.
To clean the product, a clean, dry and soft cloth is sufficient.
Dust can be easily removed using a clean, soft and long-bristled brush and a vacu-
um cleaner.
Do not use abrasive cleaning agents, rubbing alcohol or other chemical so-
lutions, which may damage the casing or even impair operation.
Disposal
The product must not be disposed of in the household waste!
Please dispose of the product, when it is no longer of use, according to the
current statutory requirements.
Technical data
Connection data ......................................230 V/AC, 50 - 60 Hz
Connection power...................................Ohmic load: max. 3680 W (230 V/AC, 16 A)
....................................................................Inductive load: max. 460 W (230 V/AC, 2 A)
Devices with mainly resistive load are e.g., light bulbs, heaters, etc.
Devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy saving bulbs, etc.
Switch type ..............................................Relay (single-pole)
Temperature setting range ....................+5 °C bis +30 °C
Accuracy ..................................................±1 °C
Backup battery ........................................
yes, built-in permanently (NiMH, 2,4 V, 40 mAh);
Charging time ca. 8 - 12 h, Back-up time ca. 200 h
Socket with child protection .................yes
Ambient conditions ................................. Temperature 0 °C to +40 °C; humidity 20% to
90%, non-condensing
Dimensions...............................................60 x 110 x 77 mm (W x H x D, including plug)
Weight .......................................................136 g
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Renkforce MH-850T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Renkforce MH-850T in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info