585218
5
Zoom out
Zoom in
Previous page
1/9
Next page
d) Placement of the connected heater/air conditioner
Please comply with the operating instructions of the heater/air condition-
er that you connect to the room thermostat.
For safety reasons, many heaters/air conditioners must not be operated
without supervision.
In any case, keep a sufficient distance between the heater/air conditioner
and flammable items (e.g. curtains).
Place a portable heater/air conditioner only on a stable, flat, level surface.
Never cover the heater/air conditioner.
Keep the heaters/air conditioners out of the reach of children! There is not
only the risk of injury or burns but also the risk fatal electric shock!
Do not connect multiple heaters/air conditioners to the room thermostat.
Make sure that the connected heater or cooling device is set up and oper-
ated far away enough from the room thermostat, so as to ensure as little
mutual interference as possible. Otherwise, switching processes occur
unnecessarily often.
Preparation
Type labels in different languages are included in the package. Stick the language
label in your language over the German language label on the back of the room ther-
mostat.
Initial start-up, recharging the integrated accumulator
The room thermostat features a built-in NiMH battery. The battery serves to prevent
data loss in the event of a power failure (back-up time up to 200 h).
Furthermore, the room thermostat (with fully charged battery) can be pro-
grammed even if it is not connected to a mains socket.
The battery is fully charged if the room thermostat has been connected to
the mains voltage for approx. 8 - 12 hours.
At delivery, the NiMH battery is usually empty. Nothing is shown in the display. In order
to perform the programming in this case, connect the room thermostat to a mains
socket. Shortly after, the display will be activated and you can start up the room ther-
mostat.
Controls
89
1
2
3 4
5
6
7
1 Control LED
LED off: The room thermostat is switched off
LED red: The set temperature limit has not been reached and the front outlet of the
room thermostat is deactivated
LED green: The set temperature limit has been reached and the front outlet of the
room thermostat is activated
2 Current temperature
3 Symbol “
“ for heating mode (the front outlet is switched on when the installed
temperature limit is exceeded)
4 Symbol “
“ for cooling mode (the front outlet is switched on when the installed
temperature limit is not met)
5 Current temperature limit (not visible when the room thermostat is switched off
and the control-LED (1) is not lit)
6 “RESET” button: Reset the room thermostat to the default setting
7 F“ button: Reduce the temperature limit
8 S“ button: Increase the temperature limit
9
” button: Switching the room thermostat on/off
The symbol “ “ or “ “ only appears when...
the room thermostat is switched off
the temperature limit of the switched-on room thermostat is reached
Placement of the room thermostat
The temperature sensor is installed permanently in the room thermostat. For this rea-
son, the room thermostat measures the temperature of the location where it is oper-
ated (e.g. when it is plugged to a wall outlet).
In a closed room, the cool air sinks and warm air rises.
For this reason, it may be necessary that the temperature limit is chosen ac-
cording to when the room thermostat should switch on a heater or a cooling
device.
Also make sure that the connected heater or cooling device is set up and
operated far away enough from the room thermostat, so that the mutual
interference is as little as possible. Otherwise, switching processes occur
unnecessarily often.
Consequently, the room thermostat should never be operated close to furni-
ture or covers because they prevent the air circulation in the room.
Connect the room thermostat in the mains outlet (wall-socket),
so that the display is on top and the front outlet is below. In this
position, the temperature sensor is located at the bottom of the
room thermostat (see the circle mark on the picture on the right),
whereby it is not or only minimally affected by the heating from
the room thermostat itself.
With another operating position, the heating-up of the
room thermostat would have greatly affected the tem-
perature sensor and it would consequently lead to swit-
ching on/off at a temperature that greatly deviates from
the installed temperature limit.
Selecting the temperature unit °C or °F
Turn off the thermostat with the button “ “ (9) so that the control-LED (1) goes off.
Press and hold both of the buttons F(7) and S(8) at the same time for about
3 seconds to switch between the temperature unit °C (Celsius degree) and °F (Fah-
renheit degree).
Choosing the operating mode
The room thermostat has two operating modes:
1. Heating mode
In this operating mode, the room thermostat turns on the connected device when the
room temperature sinks below the installed temperature limit. This operating mode is
therefore suitable for connecting to a heater.
2. Cooling mode
In this operating mode, the room thermostat turns on the connected device when the
room temperature goes above the installed temperature limit. This operating mode is
therefore suitable for connecting to a cooling device.
To switch between operating modes, proceed as follows:
Turn off the thermostat with the button “
“ (9) so that the control-LED (1) goes off.
The operating mode currently installed in the room thermostat appears at the top of
the screen (“ “ = Heating mode, “ “ = Cooling mode).
Press and hold both of the buttons
“ (9) and “S(8) at the same time for 3 sec-
onds to switch between operating modes.
Installing temperature limit
The temperature limit shown at the lower right corner of the display can be reduced
with the button F(7) or increased with the button S(8) (hold the corresponding
button longer for a quick adjustment).
The installation is only possible when the room thermostat is switched on.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Renkforce MH-850T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Renkforce MH-850T in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info