587853
25
Zoom out
Zoom in
Previous page
1/32
Next page
Jp6
SM1 SM2 SM3 SM4
MF
FL
HF
Jp12
M
T
JP1
M
1Jp 3
N
V
L
C
Ec
F
O
PL
O
HP
HP
LP
Jp11
OPT
Jp9 Jp10 Jp7 Jp8
Jp14
1JP
Jp3
Jp5
FJp
JpC
Jp4
REH REL
AUX EC
CPU
Connecting the outdoor
component
Proceed as follows to connect the
cable:
1. Remove the cover from the
unit.
2. Remove the side panel next to
the terminals.
3. Select the cable cross-section
according to the relevant
standards.
13
Connecting the outdoor component
Electrical connection diagram
Connection SV 261-681
Fit the defrost sensor for the outdoor
component on the pipe bend in the
lower third of the liquefier.
Indoor unit
Outdoor
component
N
N
L
L
Neutral conductor
Phase conductor
N
L
Control conductor
C
3
Compressor
contator
230 V~,
50 Hz,
L / N / PE
Mains cable
Earth conductor
PE PE PE
V
2
Reverse flow valve
F
1
Fan motor
Control conductor
Control conductor
4. Feed both cables through the
edge protection rings on the
fixed connection panel.
5. Terminate the cables as shown
on the electrical connection
diagram.
6. Support the cable in the strain
relief and re-assemble the unit.
(Fig 13).
Electrical circuit diagram
SV 261-681 IT
Legend
L = Phase conductor
N = Neutral conductor
= Earth conductor
F = Fan motor
C = Compressor control
V = Reverse flow valve
LP/LP = Low pressure switch (external
only)
HP/HP = High pressure switch (external
only)
O/O = Deforst sensor outdoor component
Vaporiser sensor
Air circulation sensor
Cable for remote control
(accessory)
Float switch
Condensation
Fan motor
Condensation pump
Defrost sensor
Outdoor component
Display
Swing motor 1-4
Jumper
Jumper
Transformer
25
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO SV681 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO SV681 in the language / languages: English as an attachment in your email.

The manual is 3,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO SV681

REMKO SV681 User Manual - German - 32 pages

REMKO SV681 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info