7. Fault code P2: low pressure fault
Is the connecting cable
from the lower pressure
switch to the main
board OK?
Correct
connection
No
Yes
Low pressure switch
may be defective
Bypass the low pressure
switch on the circuit
board. Does the unit
work now?
Replace the high
pressure switch
Yes
Switch off unit
No
Yes
Is the outdoor
temperature too low?
Check refrigerant
pipes
The refrigerant pipes
may be leaking
No
Check the refrigerant
pipes with leak
detection spray or an
electronic leak detector
Yes
Check the refrigerant
pressure with a
manometer. Is the
refrigerant pressure less
than 1.4 bar?
Refrigerant pipe may
be blocked
No
Siphon off refrigerant,
replace pipe / remove
blocked, perform
pressure test, drawn
vacuum and refill
No
Replace outdoor com-
ponent main board
REMKO RXT...DC
42
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXT1401 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXT1401 DC in the language / languages: English as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RXT1401 DC

REMKO RXT1401 DC User Manual - German - 56 pages

REMKO RXT1401 DC User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info