726581
27
Zoom out
Zoom in
Previous page
1/84
Next page
1
1
A
Fig. 26: Hooking in the unit
1: Structural component
Distance A
RVD 355 DC IT 290 mm
RVD 525 DC IT 290 mm
RVD 685 DC IT 275 mm
RVD 1055 DC IT 275 mm
A
1
2
3
Fig. 27: Fastening the unit
A: Distance A
1: Ceiling
2: Suspended ceiling
3: Unit housing
Indoor units
Distance
A
Suspended
unit
RVD 355-525 DC IT 23 mm 545x523 mm
RVD 685-1055 DC IT
10-18
mm
780x680 mm
Fresh air connection
The unit is prepared for the intake of fresh air.
1
Fig. 28: Fresh air connection
1: Fresh air connection
NOTICE!
Only use one fresh air connection
NOTICE!
The unit is factory filled with dry nitrogen for
leak testing purposes. The pressurised nitrogen
is released when the union nuts are undone.
Fresh air connection
The unit can also be employed to suck in and reg-
ulate the temperature of fresh air (outdoor air), in
addition to room air
. This is the preferred option for
rooms with a high rate of air consumption.
n Observe the regional regulations concerning
air treatment.
n Fit a collar with a nominal diameter of 65 mm
to the fresh air connection (Fig. 29
).
27
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RVD 355 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RVD 355 DC in the language / languages: English as an attachment in your email.

The manual is 5,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RVD 355 DC

REMKO RVD 355 DC User Manual - German - 84 pages

REMKO RVD 355 DC User Manual - Dutch - 84 pages

REMKO RVD 355 DC User Manual - French - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info