587567
8
Zoom out
Zoom in
Previous page
1/16
Next page
8
Prior to Initial Operation
The unit is set up in the desired location with the air out-
let side facing the room. Follow the safety instructions
when setting up the unit.
Keep doors and windows closed
during operation.
In case of direct sunlight, make sure
to close all curtains and blinds.
Recommendations for optimum unit operation.
5 MIN.
There must be a minimum of 20 cm between the
back of the unit and the wall.
Expelling the warm air
During cooling mode, the unit generates warm air. This
air must be expelled from the room to retain the cooling
effect.
It is therefore necessary to insert the supplied exhaust
hose into the air outlet opening at the back of the unit.
The exhaust hose must always be placed at an in-
cline in the direction the air is flowing!
In some circumstances, low pressure can occur in the
setup room when air is being expelled via a perma-
nently attached exhaust hose, e.g. as a result of closed
windows or doors. If the performance of the unit is ad-
versely affected as a result, make sure that the pressure is
corrected.
Make sure that the deflector piece
from the top slides down into the
notches on the side until it clicks into
place.
To ensure that the unit operates ef-
fectively, do not place the flexible ex-
haust hose supplied at sharp angles
and make sure there are no kinks.
Different ways of expelling air
You can expel air from the building as follows:
1. With a flat nozzle.
The flat nozzle supplied can be
used in different ways.
It is possible to guide the flat nozzle
through the open window and se-
cure it firmly using straps and suc-
tion devices.
The flat nozzle can also be hung
through the partially opened win-
dow.
2. With a fixed connection to the ex-
haust hose (wall lead-through).
The hose supplied is firmly con-
nected to a wall lead-through.
Lead-through kits can be pur-
chased as accessories.
Circulation filter
Condensation
drain with plug
You may not extend the exhaust hose.
The air expelled from the unit contains a certain
amount of moisture. We therefore recommend ex-
pelling the air to the surroundings or the outside.
After unpacking the unit, place it on
its transport wheels and let it stand
for a minimum of 5 min. before
switching it on.
Place the unit securely on a level
and firm surface.
An uneven surface can cause vibra-
tions and disruptive noises.
Before plugging in the power cord,
make sure that the required current is
available!
230V / 1~, N, PE / 50 Hz.
If extension cords are necessary,
make absolutely sure that they are
sufficiently thick.
All extensions of the power cords
must be sufficiently thick and may
only be used if they are completely
extended.
Make sure that there is a plug for the
condensation drain and that it has
been securely placed.
Water may leak out after the unit be-
comes operational.
Never operate the unit without the
intake filter.
Without an air intake filter, the plate
fins of the evaporators become dirty
and the unit’s performance is ad-
versely affected.
Make sure that people and objects,
such as plants in the room, are not
directly in the path of the expelled air.
Exhaust filter
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL350 in the language / languages: English as an attachment in your email.

The manual is 3,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL350

REMKO RKL350 User Manual - German - 16 pages

REMKO RKL350 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info