587595
9
Zoom out
Zoom in
Previous page
1/24
Next page
9
Manual operation
The unit can be manually operated if, for example, the
infrared remote control is not functioning properly or
has been lost.
Open the air inlet grille of the indoor unit and press the
button on the right side.
The following operating modes are then activated:
MODE = Automatic
(Operating cycle of the compressor
On 20 min. Off 10 min.)
TEMP. = 24°C, FAN = Automatic
SWING = On, TIMER = Off.
Shutting Down the Unit
Temporary shutdown
1. Let the unit run in cool mode for 30 minutes at a
temperature setting of 31°C.
2. Switch the indoor unit off using the remote control.
3. Disconnect the system with the main switch or fuse
protection from the power supply.
4. Check the indoor unit for visible damage.
5. Clean the indoor unit as described in the
“Maintenance and Service” section.
6. If possible, cover the outdoor unit with a plastic
sheet to protect it from weather conditions.
Permanent shutdown
For environmental safety reasons, the air conditioners
may only be disassembled by authorised service cen-
tres.
Manual air distribution
There are individually adjustable air directing plate fins
on the air outlet side for horizontally distributing the air.
Set the air directing plate fins in the desired position
with the left and right adjustment levers.
*
Never adjust the fins when the unit is in automatic
swing mode! Do not reach into the unit!
There is a risk of injuring your hand on the fan
motor.
LED display on the indoor unit
POWER On / Off (red)
PROTECT Compressor protection (green)
RUN Compressor mode (green)
TIMER Timer mode (yellow)
Display Room temperature / target temperature
error code
The display changes to the target temperature display
when the settings are made with the remote control.
Left adjustment
lever
Right adjustment
lever
Cause
E3
RUN and TIMER LEDs blink alternately.
Unit switches off after approx. 30 seconds.
Fan motor
E5 TIMER LED blinks. Room air sensor
E6 RUN LED blinks. Frost protection
sensor
E9 The LEDs blink alternately for 20 minutes.
Unit switches off after another 20 minutes.
Insufficient refriger-
ant
LED error code
First, remedy the cause of the problem and then reset
the error code display by switching the unit off and off.
Malfunction display
1 Indoor unit ML ...-IT
2 Outdoor unit ML ...-AT
3 Infrared remote control
4 Refrigerant pipes
5 Air inlet grille
6 Air outlet fin with swing motor
7 Manual air directing plate fin
(covered)
System Structure
11
3
4
7
8 9
Outside
Inside
2
1
14
12
10
13
6
15
5
8 Display
9 Receiver
10 Manual mode switch
11 Condenser fan
12 Wall lead-through
13 Shut-off valve
14 Condensation connection ML ...-IT
15 Air outlet
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML520 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML520

REMKO ML520 User Manual - German - 28 pages

REMKO ML520 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info