Commissioning
Prior to initial operation, the air
intake and outlet openings must
be inspected for foreign bodies
and the air in take filter for dirt.
Blocked or dirty grilles and filters
must be cleaned immediately. See
the chapter “Maintenance and
Service“.
Cooling mode
1. Switch the unit on with the
“I/O” button. .
2. Select cooling mode with the
“Mode” button.
The “AUTO” LED must be lit
up.
3. Set the target temperature you
want with the „TIMER/TEMP/
ADJUST“ buttons.
The selected target temperature
appears on the display.
If the set fan speed is too high
or too low, the desired fan
speed can be set by pressing
the “FAN SPEED“ button.
Fan mode (circulation)
1. Switch the unit on with the
“I/O” button
2. Select fan mode with the “FAN
SPEED” button.
The LED „HIGH/MED/LOW“
must be lit up.
Wall lead-through
The hose supplied is firmly con-
nected to a wall lead-through.
Lead-through kits can be
purchased as accessories. (Fig. 3).
3 Wall lead-through
In some circumstances, low
pressure can occur in the
setup room when air is being
expelled via a permanently
attached exhaust hose, e.g. as
a result of closed windows or
doors. If the performance of
the unit is adversely affected
as a result, make sure that the
pressure is corrected
NOTE
Shut-down
Temporary Shut-down
If the unit is to be taken out of
operation for a longer period of
time, for example, over the winter,
proceed as follows:
1. Let the device run for appro-
ximately 2 hours in circulation
mode (FAN) to dry the surface
of the evaporator plate fins.
This removes the remaining
moisture from the unit and
prevents unpleasant odours
when the device is put back
into operation.
2. Switch off the unit by pressing
the “I/O” button, unplug the
unit from the power supply and
roll up the power cord.
Make sure that the cable is not
bent and there are no kinks.
3. Place a suitable container under
the condensation drain of the
internal tank. The condensation
drain is located at the bottom
at the back of the unit.
4. Pull the plug from the con-
densation drain and collect the
water that drains out.
5. Then replace the plug.
Keep in mind that if there is no
plug or it is inserted incorrectly,
water may leak out after the
unit has resumed operation.
6. Store the unit in an upright
position in a dry location.
that is protected from direct
sunlight and dust.
To prevent dust from getting
inside the unit, protect it with,
for example, a plastic cover.
1
Exhaust by opened Win
dow
2
Exhaust by part. opened Win
dow
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO MKT290 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO MKT290 in the language / languages: English as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO MKT290

REMKO MKT290 User Manual - German - 20 pages

REMKO MKT290 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info