5.4 Installation
Perform the installation as follows:
1. Cut the required holes out of the mounting
template.
2. Fasten the mounting template to the wall.
Ensure that this is level.
3. Mark the required core holes, the fastening
points for the mounting rails and the holes for
the condensate drain and the lift protection
bracket.
A
A: Inside
4. Remove the mounting template.
5. Using a corresponding core drill machine,
drill two 162 mm diameter holes in the wall
for the air supply and exhaust air (the pilot
hole should be 5-10 mm. Use an incline of
approx. 3% to prevent the penetration of
water from outside.
A
A: Inside
6. Drill the remaining holes for the condensate
drain (min. 18 mm), the wall bracket and the
lift protection bracket. The condensate drain
must have an incline of at least 3 %.
7. Insert the supplied plastic sheets into the drill
holes and cut off the excess material so that
the plastic sheets on the outside are 5 mm
shorter than the wall thickness. Ensure that
the junction line points upwards. Then insert
the condensate hose into the hole provided.
NOTICE!
If heating mode must be used, it is recom-
mended to insulate the plastic sheets
from outside to prevent condensation in
the wall.
5 mm
A
A: Inside
REMKO series KWT
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWT 240 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWT 240 DC in the language / languages: English as an attachment in your email.

The manual is 3,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWT 240 DC

REMKO KWT 240 DC User Manual - German - 32 pages

REMKO KWT 240 DC User Manual - Dutch - 32 pages

REMKO KWT 240 DC User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info