5 Assembly and
installation
5.1 Important notes
prior to installation
When installing the unit, observe the following
points:
nThe installation must be carried out on a flat
wall
nEnsure that the wall meets the static require-
ments (consider the weight of the device as
well as the required holes to be drilled)
nEnsure that the minimum clearances are
observed to allow trouble-free maintenance
and/or servicing
nEnsure that no water pipes, power cables or
similar are inside the wall of the installation
area as they could be damaged by drilling
holes
nEnsure that there are no adjacent objects
which may obstruct the air circulation
nDo not install the unit in close proximity to or
above heat sources or electrical devices
nBy correctly placing the unit, ensure that the air
stream is not directly aimed at people
nA mains socket suitable for a plug with protec-
tive contact, must be provided in the vicinity of
the system
5.2 Minimum clearances
Observe the minimum clearances to allow access
for maintenance and repair work and facilitate
optimum air distribution.
A
B
D
C
Fig. 6: Minimum clearances
KWT 240 DC (all measurements in mm)
A 60
B 120
C 60
D 50
Observe minimum clearances even outside and
ensure that vegetation and plants also keep to the
minimum distances. Heavy contamination of the
condenser and increased maintenance costs must
be expected if there are leaves or needles in the
vicinity of the ventilation ducts.
Furthermore, depending on the region, ensure that
the ventilation ducts are not blocked with snow to
prevent the entry of snow into the unit or limitation
of the air flow.
> 800 mm
Fig. 7: Minimum clearances
5.3 Installation materials
The unit must be fastened to a suitable wall using
the wall bracket with sufficient screws. Only use
suitable fastening materials for your application
case.
13
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO KWT 240 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO KWT 240 DC in the language / languages: English as an attachment in your email.

The manual is 3,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO KWT 240 DC

REMKO KWT 240 DC User Manual - German - 32 pages

REMKO KWT 240 DC User Manual - Dutch - 32 pages

REMKO KWT 240 DC User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info