587907
25
Zoom out
Zoom in
Previous page
1/44
Next page
25
Type C13 horizontal/coaxial
L1 + L2 maximum pipe length
without end pieces
ø 80 ø 100
Model Metres
GPM15 10 + 10
GPM25 10 + 10
GPM35 10 + 10
GPM55 4.5 + 4.5
GPM75 4 + 4
Type C33 vertical/coaxial
L1 + L2 maximum pipe length
without end pieces
ø 80 ø 100
Model Metres
GPM15 11 + 11
GPM25 11 + 11
GPM35 11 + 11
GPM55 4.5 + 4.5
GPM75 4 + 4
Gas appliance Type C
Non-roomsealed combustion
system.
The combustion system is tight
with respect to the environment in
which it is installed.
The combustion air is supplied
from the outside.
The pipes run horizontally through
the outside wall or vertically via
the roof.
L1
KO
L2
Mounting height
Side view
2.5 - 3.5 m
L1
L2
Mounting height
2.5 - 3.5 m
Side view
L1 L2
Mounting height
2.5 - 3.5 m
Front view
Type C33
Non-roomsealed combustion
system.
The chimney and combustion air
ducting is routed via the roof using
a LAS end piece.
Type C13
Non-roomsealed combustion
system.
The chimney and combustion
air ducting is routed through the
outside wall using a LAS end piece.
We reserve the right to make changes to dimensions and design in the interest of technological advances.
Condensate connection [KO] =
M 30 external thread
NOTE
The installation of chimney
pipes through outside walls
must comply with the
requirements of DVGW - TRGI
and TRF and be approved
by the local master chimney
sweep.
NOTE
With this type of unit, the
position of the connections
on the unit must be changed,
i.e. they must be routed from
the rear upwards.
This variant
is provided at the factory
and must be specifi ed when
ordering.
NOTE
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO GPM 35 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO GPM 35 in the language / languages: English as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO GPM 35

REMKO GPM 35 User Manual - German - 44 pages

REMKO GPM 35 User Manual - Dutch - 44 pages

REMKO GPM 35 User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info