Code Display text Description Adjustment range Submenu 135 160
AP090 Installer phone Telephone number of the installer Mandatory
bus master
6 6
CP040 Postrun zone
pump
Pump post runtime of the zone 0 - 20 Min CH 0 0
CP240 ZoneRoomUni
tInfl
Adjustment of the influence of the
zone room unit
0 - 10 CH 3 3
CP250 CalSondeAmb
Zone
Calibration of Zone Room Unit -5 - 5 °C CH 0 0
CP290 ConfigZone
PumpOut
Configuration of Zone Pump Out
put
0 = Zone output
1 = CH mode
2 = DHW mode
3 = Cooling mode
4 = Error report
5 = Burning
6 = Service flag
7 = System error
8 = DHW looping
CH 0 0
CP510 Temporary
Room Setp
Temporary room setpoint per zone 5 - 50 °C CH 20 20
GP030 Flue Gas Temp
Max
Maximum flue gas temperature 20 - 200 °C Commercial
boiler
120 120
GP048 Fan PWM Min Minimum Pulse Width Modulation
for the fan controller
0 - 100 % GVC Pneu
matic
10 10
GP050 Power Min Minimum power in kilo Watt for
RT2012 calculation
0 - 300 kW Commercial
boiler
5.3 5.3
GP056 Grad. 1 power
reduct
Factor of power reduction when
temperature gradient > parHeDTh
MaxLevel1 is detected
0 - 1000 Commercial
boiler
1 1
PP017 ChPumpSpeed
MaxFactor
Maximum central heating at mini
mum load as percentage of max
pump speed
0 - 100 % Commercial
boiler
30 30
9 Maintenance
9.1 Maintenance regulations
Important
The boiler must be maintained by a qualified installer in
accordance with local and national regulations.
Important
Adjust the frequency of inspection and service to the conditions of
use. This applies especially if the boiler is:
In constant use (for specific processes).
Used with a low supply temperature.
Used with a high ΔT.
9 Maintenance
7701838 - v.09 - 10122021 45
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta Ace 160 - T Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta Ace 160 - T Control in the language / languages: English as an attachment in your email.

The manual is 3.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info