805749
44
Zoom out
Zoom in
Previous page
1/76
Next page
Code Display text Description Adjustment range Submenu 135 160
EP014 SCB func. 10V
PWMin
Smart Control Board function 10
Volt PWM input
0 = Off
1 = Temperature control
2 = Power control
0-10 volt in
put
0 0
GP007 Fan RPM Max
CH
Maximum fan speed during Cen
tral Heating mode
1000 - 8500 Rpm Commercial
boiler
5700 6700
GP008 Fan RPM Min Minimum fan speed during Central
Heating + Domestic Hot Water
mode
900 - 8500 Rpm Commercial
boiler
GVC Pneu
matic
1900 1900
GP009 Fan RPM Start Fan speed at appliance start 900 - 5000 Rpm Commercial
boiler
GVC Pneu
matic
2200 2200
GP010 GPS Check Gas Pressure Switch check on/off 0 = No
1 = Yes
Commercial
boiler
0 0
GP021 Temp diff Modu
lating
Modulate back when delta temper
ature is larger than this threshold
5 - 25 or 40 °C Commercial
boiler
40 25
GP022 Tfa Filter Tau Tau factor for average flow tem
perature calculation
0 - 255 Commercial
boiler
1 1
GP024 VPS Check Valve Proofing System check on /
off
0 = No
1 = Yes
Commercial
boiler
GVC Pneu
matic
0 0
PP007 Min anti-cycle
time
Minimum heat generator holding
time that can be reached after a
stop
0 - 20 Min Commercial
boiler
3 3
PP012 Stabilization
time
Stabilization time after heat gener
ator start for central heating
5 - 180 Sec Commercial
boiler
30 30
PP015 CH Pump post
run time
Central heating pump post run
time
1 - 99 Min Commercial
boiler
1 1
PP016 Max. CH pump
speed
Maximum central heating pump
speed (%)
20 - 100 % Commercial
boiler
100 100
PP018 Min CH pump
speed
Minimum central heating pump
speed (%)
20 - 100 % Commercial
boiler
20 20
PP023 CH Hysteresis Temperature hysteresis for the
generator to start on central heat
ing
1 - 25 °C Commercial
boiler
10 10
Tab.42 Navigation for advanced installer level
Level Menu path
Advanced installer > Installation Setup > FSB-WHB-HE-150-300 > Submenu (1) > Parameters, counters, signals >
Parameters > Advanced
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
Tab.43 Factory settings at advanced installer level
Code Display text Description Adjustment range Submenu 135 160
AP002 Manual Heat
Demand
Enable manual heat demand func
tion
0 = Off
1 = With setpoint
2 = TOutdoor Control
Commercial
boiler
0 0
AP026 Setpoint manual
HD
Flow temperature setpoint for
manual heat demand
7 - 90 °C Commercial
boiler
40 40
AP056 Outdoor sensor Enable outdoor sensor 0 = No outside sensor
1 = AF60
Outdoor
tempera
ture
1 1
AP089 Installer name Name of the installer Mandatory
bus master
8 Settings
44 7701838 - v.09 - 10122021
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Quinta Ace 160 - T Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Quinta Ace 160 - T Control in the language / languages: English as an attachment in your email.

The manual is 3.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info