2. Lead the main electrical cables through the holes (1).
3. Connect the electrical cables.
3.1. Make sure that the phases are connected in a right-rotating
field in the phase order: L1, L2, L3.
3.2. In case of an extension of the sensor cable, it is necessary to
use a shielded cable with a cross section of at least 0.75 mm2.
3.3. Do not install the sensor cable together with the mains power
cables.
4. Connect the controller cable to the device.
4.1. Use one, or if necessary several, separate external main
switches upstream to the terminal box to be able to separate
the device completely from the network.
5. If applicable, connect the heat tracing cables of the condensate
drainage.
6. Insulate the cables.
See also
Electrical connections, page 13
6.4 Filling the system
6.4.1 Filling the system
Caution
The heating circuit must have a sufficient water flow to operate
the heat pump. Insufficient or no hot water flow can lead to high
pressure failures in heating mode and low pressure failures in
defrost mode. If this happens, the system will be switched off by
either the high pressure limiter or the low pressure limiter.
Wrong settings on the controller can have a similar effect.
When filling the hydraulic system, please make sure the water
temperature in the system is above 10°C, and the ambient
temperature is above 0°C. The machine will not start when the
water in the system is under 10°C to protect itself.
Important
Failures in the heat pump are mostly caused by hydraulic
operation conditions and lack of water flow over the condenser. If
a malfunction is displayed, it is often to protect the heat pump. It is
generally not a sign of a defective heat pump.
Fig.22 Entry electrical cables 44
AD-3001695-01
1
Fig.23 Entry electrical cables 88
AD-3001697-01
1
Fig.24 Entry electrical cables 168
AD-3002171-01
1
6 Installation
32 7697291 - v.05 - 11032022
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha E-HP AW 44 Cool Plus B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha E-HP AW 44 Cool Plus B in the language / languages: English as an attachment in your email.

The manual is 12.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info