805754
20
Zoom out
Zoom in
Previous page
1/44
Next page
-X2
7-N-PE Solar pump
230V, max. 1A
8-N-PE Suction Pump
230V, max. 1A
Tab.30 Connections -X3
-X3
3-4 Flow / Pressure switch
9-10 External thermostat
11-12 Remote on / off
13-14 Smart Grid 1 / Tariff
15-16 Smart Grid 2 / Tariff
17-18 Deactivation return pump
Tab.31 Connections -X5
-X5
1-2 Central fault
Tab.32 Connections -X6
-X6
1-2 Outside temperature
3-4 Hot water temperature
7-8 Mixing circuit temperature 2 collector tempera
ture
9-10 Set point, Space, Buffer or Heating solar stor
age tank temperature
11-12 Buffer tank sensor
15-16 Control of the return pump 0-10V
19-20 Control mixer 2 0-10V
4 Description of the product
4.1 Product types
There are different types of the E-HP AW heat pump:
E-HP AW 44 Ace B
E-HP AW 88 Ace B
E-HP AW 168 Plus B
E-HP AW 44 Cool Ace B
E-HP AW 88 Cool Ace B
E-HP AW 168 Cool Plus B
The naming of these products is to be interpreted as follows:
E-HP AW: Electrical heat pump air/water.
Number: the capacity of the E-HP AW in kW.
Cool: indicates that the device is equipped with an active cooling option.
B: indicates that it is version 2 of the product.
Plus/Ace: indicates the operating limits of the device. The Ace can be
used at lower outdoor temperatures and deliver a higher flow
temperature.
4 Description of the product
20 7697291 - v.05 - 11032022
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha E-HP AW 44 Cool Plus B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha E-HP AW 44 Cool Plus B in the language / languages: English as an attachment in your email.

The manual is 12.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info