597827
176
Zoom out
Zoom in
Previous page
1/250
Next page
RED SCARLET-X OPERATION GUIDE
COPYRIGHT © 2013 RED.COM, INC
955-0003_v4.0, Rev-A | 176
SYNC (VIDEO SYNC)
A 4-pin LEMO connector supports shutter synchronization, GPI, timecode and genlock input signals.
The shutter Sync input signal acts as an immediate response hardware trigger to commence a scan. This is
useful for motion control and other applications where the camera is driven by a master timing device.
Alternatively, this input may be used as a GPI (General Purpose Input) trigger, whose function is
programmed in the USER KEYS menu. Default function for the GPI trigger is Record Start / Stop.
The SMPTE timecode input provides a frame accurate time stamp for each frame of recorded video. External
TC must be chosen in the Project > Timecode menu. When SMPTE timecode is detected it will align the
internal TC value to the external TC signal at every :00 frame crossing of the external TC signal.
The Video Genlock input may be used as a vertical interval reference signal for the sensor and HD-SDI
outputs when precise synchronization is required between cameras, such as for 3D and live broadcasts.
NOTE: HD-SDI monitor outputs will automatically sync to the external GENLOCK signal as soon as it is
detected, there is no need to enable this function. Sensor shutter sync to GENLOCK is only supported with
HD-SDI. Sensor shutter sync to GENLOCK is not possible when using HDR. Selecting GENLOCK sync mode
will disable HDR.
View into Camera SYNC (Video Sync) Interface Connector
Mating Connector: FGG.00.304.CLAD27Z
PIN
SIGNAL
DESCRIPTION
1
GROUND
Common Ground
2
SS/GPI
Shutter Sync / GPI Trigger Input
3
TIMECODE
SMPTE unbalanced timecode Input
4
GENLOCK
RS170A Tri-Level Sync Input
NOTE: The Camera Brain’s Shutter Sync / GPI Trigger uses a 3.3 V Schmitt trigger (5 V tolerant). It is not a
switch closure circuit. Therefore, it requires current supplied by the trigger source. Both edges of the input
signal may be used as a trigger.
176


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Red Scarlet X 4.0 - 2013 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Red Scarlet X 4.0 - 2013 in the language / languages: English as an attachment in your email.

The manual is 18,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info