RED ALERT! reads the camera metadata recorded for each parameter. Individual values can be
changed by dragging the slider, or by entering a new numeric value in the box. Clicking R will
reset the value back to its default setting. Clicking M will restore the recorded metadata value.
R ALL or M ALL will affect all parameters, GRADE will revert all values back to those last used
in your color grade.
Presets are available to establish a consistent “look” across multiple clips, or alternative color
treatments may be made to the same clip. In future, looks may be shared with the camera.
The image may be displayed using REC 709, linear or a variety of log color space. If Matrix is
unchecked and display is set to Linear, the data that is drawn on screen represents the native
linear response of Mysterium™ without any color processing or gamma correction applied. For
most television applications, select REC 709. For special effects, use Linear. For D.I use a Log.
The timeline controls permit the user to play selected clips and mark an IN and an OUT points,
between which the TIFF or DPX file sequence will be extracted. When creating any QuickTime
reference movies the entire clip will be referenced, as trimming will be performed downstream.
If a single frame is to be exported, press Save 4K or 2K DPX, or 4K or 2K TIFF. If a sequence
of frames is desired, press Save Sequence 4K or 2K DPX, or 4K or 2K TIFF.