500594
5
Zoom out
Zoom in
Previous page
1/28
Next page
5
6. HOW TO INSTALL CORRECTLY YOUR RF SYSTEM
* For maximum radio sensibility, the active antenna must be placed at a minimum of 0.50 cm of any metallic
surfaces (Electrical Box) or vertical metallic pipes.
7. RF INITIALIZATION (Assign RF Thermostats to zones)
To enter RF Initialization Mode, press the (OK) during 5 s, then the green LED blinking cursor must be appear (The
LED 1 must be blink in green).
Note:
If it’s the first “RF initialization” all the other LED must be off.
If a “RF initialization” has already made, the zones already assigned must be shine in green fixed.
1. Use (◄) or (►) keys to change the zone, the green LED blinking cursor move in a same way.
- With (OK) key you can select or de-select the zone(s) which must be learned with a thermostat. The
corresponding LED of the selected zone(s) must be shine in red to indicate that this zone(s) is in wait of thermostat
signal.
2. When you have correctly selected the zones which must be assigned with a RF thermostat go to the
thermostat and activate the “rF init” mode. (See the corresponding leaflet of the RF thermostat to do this).
3. Now the thermostat will send the learning message to the MASTER-RF, Check the good reception on the
MASTER-RF,
- The LED previously selected (in RED) must now shine in green to indicate that the zones are correctly configured
with the thermostat.
- You can now switch off the thermostat to avoid perturbation during the installation of the other thermostats.
X
Careful!
The active antenna shouldn’t be mounted near to
metallic parts.
Metallic Box
Good
The active antenna must be mounted vertically.
Metallic Box
50
cm
Careful!
The active antenna shouldn’t be placed inside the
metallic box.
Metallic Box
X
Careful!
The active antenna sensitivity will be reduced if it
mounted in horizontal position.
Metallic Box
X
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Radson 52052 - UFH MASTER RF 6 Zones at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Radson 52052 - UFH MASTER RF 6 Zones in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info