815530
14
Zoom out
Zoom in
Previous page
1/30
Next page
14 10/238106-804K
LED
Color
Number of
Flashes between
pauses Description Notes
Green
SteadyONwhile
priming feed tube
(max time 2
minutes)
FeedMotorisrunningcontinuously.
(This primes the feed tube).
Whenprimingthefeedsystemandllingthe
repot,DO NOT OVERFILL FIREPOT FOR
IGNITION. The appliance will automatically
go into start up following the prime function.
Green 1x Applianceiso󰀨andready.
To start appliance, follow start up sequence.
Green Blinks
Continuously
Appliance is in the start up/ignition
sequence or in shutdown.
During shut down, the blowers will shut o󰀨
when the exhaust temperature has cooled.
Green Varies
The number of ashes between pauses
indicatestheburnrate(1forlowupto5
for high).
Adjust the dial control to change the desired
burn rate.
Amber Blinks
Continuously Appliance is in the in shutdown sequence.
During shut down, the blowers will shut o󰀨
when the exhaust temperature has cooled.
Red
1x
Empty Hopper Alarm
This alarm is caused by the re going out
from lack of fuel.
Red 2x Exhaust Probe Alarm Failed component error. See troubleshooting
section for more information.
Red 4x MissedIgnition
There are a total of 2 tries per ignition
sequence. If after 2 tries there is no rise in
exhaust temperature this error will occur.
See the troubleshooting section for additional
information and correction.
Red 8x ExhaustGasOverTemperatureAlarm
The exhaust temperature exceeds the
allowable limit. See the troubleshooting
section for more information and correction.
K. LED Color Coding Chart and Explanation
WARNING
!
Fire Risk
DoNOToperateappliance:
With appliance door open.
Firepotooropen.
DoNOTstorefuel:
Closer than required clearances to combustibles to
appliance
Within space required for loading or ash removal.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Outfitter I - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Outfitter I - Pellet in the language / languages: English as an attachment in your email.

The manual is 4.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Outfitter I - Pellet

Quadra-Fire Outfitter I - Pellet User Manual - French - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info