815524
20
Zoom out
Zoom in
Previous page
1/40
Next page
20 7027-802M 04/23
Figure 20.1
Clean Out
Cover
NOTE: There are heavy duty vacuum cleaners specically
designed for solid fuel appliance cleaning.
12. Door Latch Inspection
• Frequency: Prior to heating season
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is o󰀨.
b. To adjust, open the latch and pivot the holding rod
out. Loosen the jam nut on the rod.
c. With a Phillips head screw driver, turn the rod
clockwise to tighten. The latch handle should snap
securely in place when adjusted properly.
d. After adjusting the latch, be sure to tighten the jam
nut on the rod to hold the adjustment.
13. Cleaning Exhaust Blower - Requires No Lubrication
• Frequency: Yearly or as needed
• By: Qualied Service Technician
• Task: Contact your local dealer
14. Cleaning Convection Blower - Requires
No Lubrication
• Frequency: Yearly or as needed
• By: Qualied Service Technician
• Task: Contact your local dealer.
15. Cleaning the Top Vent Adapter
a. The appliance must be in complete shutdown
and the exhaust blower should be o󰀨. Allow the
appliance to completely cool down.
b. Open the clean-out cover (Figure 20.1).
c. Sweep out any ash build-up.
10. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
• Frequency: Yearly or more frequently depending on
ash build-up.
• By: Qualied Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been unplugged
and the exhaust blower is o󰀨.
The products of combustion will contain small particles of y
ash. The y ash will collect in the exhaust venting system
and restrict the ow of the ue gases.
At start-up if there is incomplete combustion, or if there is
a shutdown or incorrect operation of the appliance it will
lead to some soot formation. This will collect in the exhaust
venting system.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
11. Cleaning the Glass
• Frequency: When clear view of the re pot
becomes obscure
• By: Homeowner
a. Appliance must be completely cool before
cleaning glass.
b. Vacuum y ash from glass and door rope.
c. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe o󰀨 with dry towel.
Handle glass assembly with care.
When cleaning glass:
Avoid striking, scratching or slamming glass.
Do NOT clean glass when hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on
white lm.
Refer to maintenance instructions.
CAUTION
Handle glass doors with care.
Inspect the gasket to ensure it
is undamaged.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
WARNING
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Classic Bay 1200 Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Classic Bay 1200 Pellet in the language / languages: English as an attachment in your email.

The manual is 5.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Classic Bay 1200 Pellet

Quadra-Fire Classic Bay 1200 Pellet User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info