26 04/217027-805J
A. Blower
1. Combustion (Exhaust) Blower Replacement
PART NUMBER: 812-3381
a. Prep appliance from the blower removal:
i. Disconnect the appliance from the electrical outlet.
ii. Remove panel set and disconnect ue.
iii. Pull appliance out onto the hearth.
iv. Remove the right-side access panel, then slide out
the right-side panel of the appliance, held in place
with 2 screws, to expose the exhaust blower.
b. Remove existing blower (Figure 26.1):
i. Use the 11/32” wrench or nut driver to loosen and
remove the (6) nuts holding the motor mount plate
to the blower housing on your appliance.
ii. Remove the washer from beneath the terminal
ring on the grounding wire.
iii. Pull motor/mounting plate from blower housing.
iv. Scrape o󰀨 the old gasket material from
blower housing.
c. Install new blower:
i. The blower and blower housing is shipped as a
appliance in this kit. It is necessary to separate
them at this point.
ii. Use 11/32” wrench or nut driver to loosen and
remove the (6) nuts holding the motor mount plate
to the blower housing.
iii. Remove the washer from beneath the terminal
ring on the grounding wire.
iv. Pull motor/mounting plate from blower housing
and discard or set aside the blower housing.
v. Carefully remove gasket from new housing and
set onto the appliance blower housing.
d. Reinstall blower to blower housing:
i. Install blower on housing ensuring that wiring exits
at the 12 o’clock position. Place washer and then
grounding wire on nearest mounting plate stud.
ii. Use nuts removed in step A1 to secure blower to
housing.
iii. Reconnect wiring. Use Jumper wire if necessary.
Reconnect power supply.
e. Re-install appliance:
i. Reassemble right side panel to appliance with 2
screws previously removed.
ii. Push appliance back into the hearth.
iii. Reconnect ue and re-install panel set; plug in
appliance to electrical outlet.
Figure 26.1
Blue Wire
White Wires
Housing Bolts
Blower Mounting
Screws
5 5 Service Parts Replacement
2. Convection Blower Replacement
PART NUMBER: 812-4900
a. The blower is located at the bottom rear of the insert.
If an outside air kit is also installed, you will rst need
to remove the outside air ange by removing the 2
screws using a Phillips head screwdriver. You do not
need to remove the ex pipe from the ange.
b. Remove panel set and disconnect ue.
c. Pull appliance out onto the hearth.
d. Remove left access panel and then slide out left side
panel of appliance to expose the convection blower.
Loosen wing nut on the vacuum switch and remove
vacuum switch to allow room to remove the blower.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white
and the wires from the blower are black.
f. The blower is held in place with a magnet. A wing
nut and plate are installed at the factory for shipping
purposes only. This can be removed once the
appliance is installed. Lift up blower from the magnet
and remove.
g. Re-install in reverse order.
Shock Risk.
Do NOT remove grounding prong
from plug.
Plug directly into properly grounded 3
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front
of appliance.
CAUTION
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Classic Bay 1200 - Pellet - Insert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Classic Bay 1200 - Pellet - Insert in the language / languages: English as an attachment in your email.

The manual is 9.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Classic Bay 1200 - Pellet - Insert

Quadra-Fire Classic Bay 1200 - Pellet - Insert User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info