815528
25
Zoom out
Zoom in
Previous page
1/40
Next page
25 02/237022-802K
A. Blowers
1. Combustion (Exhaust) Blower
PART NUMBER: 812-4400
a. If you have adequate clearance you will not have to
remove the panel set and disconnect ue, if not then
you will have to remove the panel set and disconnect
the ue.
b. Pull appliance out onto the hearth.
c. Remove right cast side.
d. Disconnect the white and blue wires from the blower.
e. Remove blower mounting screws (not housing bolts),
Figure 25.1, from blower housing and remove blower.
The replacement blower is shipped with a housing.
If you do not need the housing, discard it. If you do
need to the replace the housing you will also need to
replace the gasket. See Service Parts List for the part
number.
f. Re-install in reverse order.
Figure 25.1
Housing Bolts
(Do Not Remove)
Blower
Screws
5 5 Service Parts Replacement
2. Convection Blower
PART NUMBER: 812-4900
a. The blower is located at the bottom rear of the insert.
If an outside air kit is also installed, you will rst need
to remove the outside air ange by removing the 2
screws using a Phillips head screwdriver. You do not
need to remove the ex pipe from the ange.
b. If you have adequate clearance you will not have to
remove the panel set and disconnect ue, if not then
you will have to remove the panel set and disconnect
the ue.
c. Pull appliance out onto the hearth.
d. Remove left cast side.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white
and the wires from the blower are black.
f. The blower is held in place with a wing screw.
g. Re-install in reverse order.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet - Insert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet - Insert in the language / languages: English as an attachment in your email.

The manual is 9.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet - Insert

Quadra-Fire Castile - Pellet - Insert User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info