692700
40
Zoom out
Zoom in
Previous page
1/100
Next page
40
4
OPERATION
Safe operation
This appliance is designed for gas cylinders up to 15 kg
Avoid torsional stress to the flexible tubing between gas regulator and appliance.
Torsional stress might lead to gas leakage over time!
Note:
If a new tank has just been connected, please allow at least one minute or more
for the air in the gas pipeline to purge out through the pilot hole.
If the burner flame goes out accidentally or it is blown out by wind, turn off the
heater and wait at Ieast 5 minutes or more to let the gas dissipate before re-ligh-
ting to avoid possible gas explosion.
Warnings:
The whole gas system. hose, regulator, pilot and burner should be inspected
for Ieak before use. But at least once a month and each time the gas cylinder
is changed. Check the hose assembly for sign of extreme abrasion, cuts or
wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be
replaced with a new one that conforms to IocaI standard codes. ). If it shows
signs of cracking, splitting or other deterioration it shall be exchanged for
new hose of the same length and of the equivalent quality.
Always keep a dry chemical fire extinguisher readily available.
For safety, always allow a 5-minute complete shut off period before re-ligh-
ting a hot heater.
Replace the gas tube/hose within the interval described with the hose.
REPLACING THE GAS CYLINDER
Shut off heater.
Close the valve of the gas cylinder.
Disconnect the regulator from the cylinder following the instructions that
came with your regulator.
Replace the cylinder.
Make sure there is no flame. Only when no flame: remove the plug or seal
cap from the cylinder valve.
Check for the presence and good state of the gasket before connecting the
regulator to the new cylinder
Check that the regulator seal is correctly fitted and able to fulfil its function.
Perform leak test using soapy water solution.
WARNING: only change the gas cylinder in a amply ventilated area, away
from any ignition source (candle, cigarettes, other flame producing applian-
ces, ...).
SAFETY CLEARANCE
For every kW it is necessary to have permanent ventilation of 25 cm², equally
distributed between the floor and high level, with a minimum outlet of 250
cm².
Never direct the hot air flow towards the cylinder.
Never use the heater without its cover.
Do not exceed 100 W/m³ of free room. The minimum volume of the room
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Qlima GFA 1030E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Qlima GFA 1030E in the language / languages: English, German, Dutch, French, Italian, Swedish as an attachment in your email.

The manual is 5,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info