621720
9
Zoom out
Zoom in
Previous page
1/44
Next page
14
15
Listed below are some potential problems that may occur when using the
scope. Carry out the recommended checks and troubleshooting steps in the
order listed. Please note that the table does not list all of the possible
problems. If the problem experienced with the scope is not listed, or if the
suggested action meant to correct it does not resolve the problem, please
contact the manufacturer.
Technical maintenance should be done at least twice a year, includes the
following steps:
Clean the outside metal and plastic surfaces from dust, dirt and moisture;
wipe the scope with a soft lint free cloth.
Clean the battery compartment's electric contact points using an oil-free
solvent.
Inspect the eyepiece lens, the objective lens and the IR illuminator and
gently blow off any dust and sand, and clean using lens cleaner and a soft
cloth; see section 6 “GUIDELINES FOR OPERATION”.
Always store the unit in its carrying case in a dry, well-ventilated space. For
prolonged storage, remove the batteries.
The aiming point shifts after
firing rounds. The riflescope
will not focus.
The riflescope will not focus.
The riflescope is not mounted
securely or the mount was not
fixed with thread sealant.
Wrong settings.
Check that the riflescope has been
securely mounted, make sure that the
same type and calibre bullets are being
used as when the scope was initially
zeroed; if your riflescope was zeroed
during the summer, and is now being
used in the winter (or the other way
round), a small displacement of the
aiming point is possible.
Adjust the riflescope according to the
instructions given in the Section
9 OPERATION and check the
surfaces of the eyepiece and objective
lenses and clean them if necessary from
dust, condensation, frost, etc; to prevent
fogging in cold weather, apply a special
anti-fog solution.
The riflescope cannot be
started with wireless remote
control.
Remote control is not activated.
Battery is low.
Activate the remote according
to instructions in section 15.
Install a new CR2032 battery.
The scope is used in day light at
long working distance
Check focusing of the scope in night
conditions.
After the built-in laser IR
Illuminator is activated, you
may see a slightly grainy,
non-uniform pattern which
does not impact detection
range and efficiency of
observation.
This is not a defect.
This is normal for eye safe
laser illuminators.
problem
possible cause(s) сorrective action
The riflescope
will not turn on.
The reticle is blurred
and cannot be focused
with the dioptre knob.
With a crisp image of the
reticle, the image of the
observed target that is at
least 30 m away is blurred.
Batteries have been wrongly
installed.
Oxidized contact points in the battery
compartment due to “leaky” batteries
or contact points becoming exposed
to a chemically-reactive solution.
The batteries are empty.
The dioptre cannot be adjusted
to your eyesight.
Dust and condensate are covering
the outside optical surfaces after
the riflescope was brought in from
the cold into a warm environment,
for example.
Reinstall the batteries with
the correct polarity orientation.
Clean the battery compartment,
focusing on the contacts.
Install fresh batteries.
If you wear prescription glasses with
a range of +/- 4, keep glasses on when
looking through the eyepiece.
Clean the lens surfaces with a blower
and soft lens cloth.
Let the riflescope dry by leaving it in a
warm environment for 2-3 hours.
It is recommended that you inspect the riflescope before every use. Make sure
to check for the following:
Visually inspect that the unit is free from any physical damage; cracks,
dents or signs of corrosion which may disqualify it from proper use.
Check the sturdiness and proper fit of the mounting system.
Ensure that the objective lens, eyepiece and the IR illuminator are free of
cracks, grease spots, dirt, water stains and other residue before use.
Visually inspect the condition of the battery and the battery compartment;
the battery should be free of electrolyte and oxidation residue, especially
where the battery makes contact with metal.
Verify the proper function of the following: selector switch, display
brightness adjustment knob and other operation buttons.
Verify the smoothness of the objective lens focus knob, dioptre focus knob.
Residual “ghost image” after
reticle change can be noticed
on the display.
This effect attributes to the peculiarity
of OLED display technology.
This is not a defect.
Peculiarities of CCD array
CCD arrays employed in Pulsar digital night vision devices, feature high quality. However certain
pixels (or groups of pixels) with increased luminosity (lighter or darker) are allowed. These defects
can be seen when conducting observation not only in the nighttime but in the day time too, especially
if Sum Light™ function is active. Presence of light and dark pixels and other minor defects of a CCD
array (up to 4%) are acceptable in accordance with regulations of the array producer.
Visibility on the screen of light pixels also depends on the type of CCD array, heating temperature
during operation.
9


Need help? Post your question in this forum.

Forumrules
1

Forum

pulsar-digisight-n770a

Reset search

  • Como posso receber este manual em Português
    no meu Email . gonsalves.antonio@hotmail.com Submitted on 26-4-2022 at 21:58

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pulsar DIGISIGHT N770A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pulsar DIGISIGHT N770A in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 2,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info