4 Grounding instructions
All grounded, cord-connected tools:
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This tool is equipped with an
electric cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in accordance
with all local codes and ordinances. Do not modify the plug
provided - if it will not fit the outlet, have the proper outlet
installed by a qualified electrician. Improper connection of the
equipment-grounding conductor can result in a risk of electric
shock. The conductor with insulation having an outer surface
that is green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal. Check with a qualified
electrician or service personnel if the grounding instructions
are not completely understood, or if in doubt as to whether
the tool is properly grounded. Use only 3-wire extension cords
that have 3-prong grounding plugs and 3-pole receptacles
that accept the tool's plug.
Repair or replace damaged or worn cord immediately.
Grounded, cord-connected tools intended for use on a supply
circuit having a nominal rating less than 150 volts:
This tool is intended for use on a circuit that has an outlet that
looks like the one illustrated in Sketch A in Figure 9. The tool
has a grounding plug that looks like the plug illustrated in
Sketch A in Figure 9 temporary adapter, which looks like the
adapter illustrated in Sketches B and C, may be used to
connect this plug to a 2-pole receptacle as shown in Sketch B
if a properly grounded outlet is not available. The temporary
adapter should be used only until a properly grounded outlet
can be installed by a qualified electrician. The green-colored
rigid ear, lug, and the like, extending from the adapter must be
connected to a permanent ground such as a properly
grounded outlet box.
5 Legend (fig. 1)
1. Quick tensioning clamp for saw blade tensioning
2. Fine adjustment for saw blade tensioning
3. Storage compartment for saw blades
4. Saw frame
5. Saw blade mount, top
6. Saw blade mount, bottom
7. Air nozzle
8. ON OFF switch
9. Stroke rate regulating button
10. Tilting Locking Knob
11. Connecting piece for vacuum cleaner
12. Cast steel base
13. Direct current motor
14. Saw table
15. Saw blade
16. Mains cable
17. Drill holes for fastening screws
18. Allen key with T-Handle
19. Saw blades
20. Blade guard
6 Description of machine
(also see fig. 1a and 1b)
The PROXXON mechanical scroll saw is a very solid and
robustly designed device. The heavy base made of cast
material, item 12, forms a solid basis for the expensive
mechanism of the machine which can work vibration-free,
precisely positioned and driven by an electronically controlled
direct current motor 13.
The areas of application are multifaceted. Your DSH/E is
particularly suitable for mould construction, precision
engineering model building and toy manufacture. For this
reason, it is precisely the right tool for designers, architects
(model building) and carpenters.
The large-area, saw table 14 1/8" x 10 5/8" for mitre cuts can
be titled up to 45°, is manufactured from aluminium die
casting for the highest precision and stability, and is then
ground for optimal glide properties.
The high quality saw blade mounts (5 and 6) and the innovative
quick clamping 1 also guarantee a lot of pleasure while working
and a convincing working result.
Changing the saw blades 15 is very simple with the quick
tensioning clamp. Saw blades with flat ends (without pin) are
introduced into the clamp adapter when the quick tensioning
device is released, clamped by tightening the screw and then
tightened with the tensioning device.
Changing saw blades with pins is even easier. These are
simply attached when the quick clamp is released and then
clamped using the quick clamp device.
The saw blade tensioning can then be set by the large rotary
button 2 at the top end of the arm.
Fig. 9
GROUNDING
ADAPTER
GROUNDING GROUNDING
MEANS
METAL SCREW
COVER OF GROUNDED
OUTLET BOX
<A> <B>
<C>
<D>
PIN
PIN
Proxxon_BedienAnl_DSH_US_Bel 10.06.2005 14:20 Uhr Seite 10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Proxxon DSH-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Proxxon DSH-E in the language / languages: English as an attachment in your email.

The manual is 1.94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Proxxon DSH-E

Proxxon DSH-E User Manual - German - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info