8.3 Extracting uids
Before extracting uids, remove the lter
or disposal bag (see chapters 7.6, 7.7). We
recommend using a special wet lter.
The dust extractor stops automatically when
the maximum level is reached.
CAUTION
Escaping foam and uids
Switch off the machine immediately and
empty the dirt trap.
8.4 The antistatic system
Friction inside the extraction hose causes
static electricity to develop during extrac-
tion. Operating personnel may receive un-
pleasant electric shocks while working. The
mobile dust extractor is tted with an anti-
static system as standard to discharge any
static electricity that may develop. How-
ever, always use the enclosed antistatic
extraction hose.
8.5 After nishing work
Switch off the mobile dust extractor and
disconnect the plug.
Clean the main lter automatically or man-
ually (see chapter 8.1).
Empty the dust container.
Wind the cable around the raised area on
the accessory box. Clamp the end of the
cable in the groove – see gure [10].
Fold the hose clip upwards. Wind the hose
around the suction coupling and the bracket
of the hose clip. Slide the end of the hose
over the bracket.
CAUTION
Hazardous dust
Damage to the respiratory passage
Wipe down the mobile dust extractor and
clean all accessories thoroughly using the
extractor (inside and out) before removing
from the working area.
Parts that you were not able to clean thor-
oughly must be sealed in an airtight plas-
tic bag prior to transportation.
Wear a dust mask!
The machine shall be stored indoors
only.
Place the mobile dust extractor in a dry
room inaccessible to unauthorised us-
ers.
9 Service and maintenance
WARNING
Risk of injury, electric shock
Always disconnect the mains plug from
the socket before performing maintenance
work on the machine!
All maintenance and repair work which
requires the motor housing to be opened
must only be carried out by an authorised
service workshop.
Damaged safety devices and components
must be repaired or replaced in a recog-
nised specialist workshop, unless otherwise
indicated in the operating manual.
Observe the following instructions:
- A dust test must be performed at least
once a year by the manufacturer or an
instructed person. This test may include
checks to determine whether the lter is
damaged, the machine is sealed properly
and the monitoring features are function-
ing correctly.
- During maintenance and repair work,
all components that cannot be cleaned
satisfactorily must be replaced. The old
components must be sealed in imper-
meable plastic bags prior to disposal in
compliance with applicable regulations
for this type of waste.
- For user servicing, the machine must
be dismantled, cleaned and serviced, as
far as is reasonably practicable, without
causing risk to the maintenance staff and
others. Suitable precautions include, de-
contamination before dismantling, provi-
sion from local ltered exhaust ventila-
tion where the machine is dismantled,
cleaning of the maintenance area and
suitable personal protection.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Protool VCP 480E-M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Protool VCP 480E-M in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 10,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info