566799
5
Zoom out
Zoom in
Previous page
1/12
Next page
PIN-146 MANUAL
DOUBLE OPEN JAW
AC CLAMP MULTIMETER
1. SAFETY INFORMATION
The following safety information must be observed to insure
maximum personal safety while operating this meter.
1.1 Do not operate the meter if the body of meter or the test lead
look broken.
1.2 Check the main function dial and make sure it is at the correct
position before each measurement.
1.3 Do not perform resistance test on a live power system.
1.4 Do not apply voltage between the test terminals and test
terminal to ground that exceed the maximum limit record in this
manual.
1.5 Exercise extreme caution when measuring live systems with
voltage greater than 60V DC or 30V AC.
1.6 Change the battery when the " " symbol appears to avoid
incorrect data.
2. Panel Layout
1Rotary Switch: use this switch to select functions and ranges
2Data HOLD keyIn any range, push the key, the present
display value will be locked and the " DH " symbol will appear,
push it again to exit the HOLD function and the "DH" symbol will
disappear.
3 Back light button: Push the LIGHT button to light the
backlight, it will automatically go out after approximately 5
seconds.
4) LCD Display
5Ω Input Jack, COM Input Jack, V-Jack
3. SPECIFICATIONS
3.1 GENERAL SPECIFICATIONS
Display: 3 1/2 digit LCD with a max. reading of 1999.
Polarity: Automatic negative polarity indication.
Zero adjustment: Automatic.
Overrange indication: Only the "1" or "-1" display.
Low battery indication: " "
Safety Standards: The meter is up to the standards of IEC1010
Double Insulation, Pollution Degree 2, Overvoltage Category I.
Data hold: Push the DH switch to "ON" and the DH sign will
appear on the display.
Clamp opening size: 34mm.
Operating Environment:
Temperature: 040 (32104°F), humidity80%RH.
Storage Environment:
Temperature: -2060 (-4140°F), humidity90%RH.
Power supply: 3×1.5V AAA batteries.
Dimension: 179(H)×73(W)×26(D)mm.
Weight: Approx. 325g (including battery).
3.2 ELECTRICAL SPECIFICATIONS
Accuracy is specified for a period of 1 year after calibration and at
18°C to 28°C (64°F to 82°F) with relative humidity to 75%.
3.2.1 DC Voltage
Range
Accuracy
Resolution
500V
1.0% of rdg+5digits
1V
Overload protection: 500V DC/500Vrms AC
Impedance: 10MΩ
3.2.2 AC Voltage
Range
Accuracy
Resolution
500V
0~400V
1.2% of rdg+8 digits
1V
400~500V
1.8% of rdg+20 digits
1V
Average sensing, calibrated to rms of sine wave
Frequency: 50100Hz
Overload protection: 500V DC/500Vrms AC
Impedance: 10MΩ
3.2.3 AC Current
Range
Accuracy
Resolution
2A
3.0% of rdg+10 digits
1mA
20A
3.0% of rdg+10 digits
0.01A
400A
3.5% of rdg+10 digits
1A
Average sensing, calibrated to rms of sine wave
Frequency: 5060Hz
Overload protection: AC 400A within 60 seconds
3.2.4 Resistance
Range
Accuracy
Resolution
200Ω
±(1.5% of rdg+15 digits)
0.1Ω
20kΩ
±(1.0% of rdg+15 digits)
10Ω
2000kΩ
±(1.5% of rdg+15 digits)
1kΩ
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Profile PIN-146 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Profile PIN-146 in the language / languages: Dutch as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info