low voltage that air conditioning will have more difficulty in starting, and long
starting lines may overload generator and trip circuit breakers.
For three phase connections, please contact Power Technology’s Tech support
Dept.
EXCITER FIELD COIL VOLTAGE SOURCE
Field coil DC voltage is obtained by rectifying the voltage from the phase to
neutral line of the generator output, or either appropriate terminal to provide the needed
voltage reference.
The rectifier bridge is an internal part of the static regulator. The static regulator senses
a change in the generator output and automatically regulates current flow in the exciter
field coil circuit to increase or decrease the exciter field strength. An adjustable rheostat
sized to be compatible with the regulator is used to provide adjustment of the regulator
sensing circuit.
ROTATING FIELD ASSEMBLY (ROTOR)
The rotating field assembly consists basically of four members: 1) the shaft
assembly, 2) the core assembly, 3) the field coil damper windings, and 4) balance lugs
to provide a high degree of static
and dynamic balance.
CORE ASSEMBLY
The core assembly consists of a quantity of thin steel plates compressed and
fastened together to form a single laminated assembly. The field windings are wound
around this assembly.
FIELD COIL
Field coils of heavily insulated wire are “wet” wound directly onto the poles. Field
coil leads are brought out to the rectifier assembly for connection to the source of
DC excitation voltage.
BALANCE
The rotor assembly is precision balanced to a high degree of static and dynamic
balance. Although the balance will remain dynamically stable at speeds in excess of the
design frequencies, the prime mover should be adequately governed to prevent
excessive over speed. High centrifugal forces created by excessive over speed may
damage the rotor windings and field coils.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PowerTech PTGK-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PowerTech PTGK-20 in the language / languages: English as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info