APPLIANCE LOADS
PT-3000 maybe used to supply AC voltage for appliances. With the exception of
a resistance-type load such as a heating element, requirements for appliances are usually
low. However, such loads must not be overlooked when calculating the total wattage
requirements. To avoid an overload situation, reserve capacity should also be calculated
for unanticipated appliance loads. The average power requirements for some common
electrical appliances are listed below as a guide.
DETERMINING ALTERNATOR LOAD REQUIREMENTS
CHECK
APPLIANCE WATTS REQUIRED
VCR 70
LIGHT BULB 100
RADIO 100
TELEVISION 100
STEREO 100
FRY PAN 150
HOME COMPUTER 150
REFRIGERATOR 500
TOASTER 1000
COFFEE MAKER 1200
HAIR DRYER 1200
MICROWAVE OVEN 1500
10,000 BTU A/C UNIT – COOLING 1500
10,000 BTU A/C UNIT – HEATING 2300
14,000 BTU A/C UNIT – COOLING 1900
14,000 BTU A/C UNIT - HEATING 2900
TOTAL
WATTS CHECKED
NOTE
: 120 Volts x Amps = Watts
EXTENSION CORDS
An extension cord is normally used to provide electrical power from the APU to a
remote location. The extension cord size (AWG#) and length must be adequate to safely
maintain the amperage requirements. A proper size extension cord will help minimize the
voltage drop between the APU and remote location.
AMPS
LOAD IN WATTS CORD LENGTH
120 VOLTS AWG#10 AWG#12 AWG#14
5 600 500 FT 300 FT 200 FT
10 1200 250 FT 150 FT 100 FT
20 2400 125 FT 75 FT 50 FT
30 3600 60 FT 35 FT 25 FT
22
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PowerTech PT-3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PowerTech PT-3000 in the language / languages: English as an attachment in your email.

The manual is 3,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info