676276
5
Zoom out
Zoom in
Previous page
1/10
Next page
POWAIR0805 EN
Copyright © 2014 VARO P a g e | 5 www.varo.com
It must be checked that the maximum operating speed of the machine tool is higher
than the nominal speed of the machine.
It must be checked that the hook&loop abrasive sheets can be affixed concentrically
to the mounting plate.
4.7 Hazards in the work environment
Slipping, tripping and falling are the main causes of injuries at the workplace. Keep in
mind that surfaces may have become slippery during machine use, and remember
tripping hazards caused by the air or hydraulic hose.
Proceed with caution in unfamiliar surroundings. There may be hidden dangers due
to electrical cables or other supply lines.
This machine for grinding and sawing is not suitable for use in explosive
environments and is not insulated against contact with electrical power sources.
Therefore, it may not come into contact with electrical power sources!
Verify that there are no electrical lines, gas lines, etc. that may result in a hazard in
the event of them becoming damaged during machine use.
5 ADDITIONAL SAFETY INSTRUCTIONS FOR PNEUMATIC MACHINERY
Compressed air can result in serious injuries.
Always close the air supply, release pressure from the hose, and disconnect the
machine from the compressed air supply, when the machine is not in use, before
switching accessories or when performing repairs.
Never aim the air flow at yourself or others.
Hoses flapping about can result in serious injuries. Therefore always inspect hoses
and their fasteners for damage and a secure fit.
If using universal swivel couplings (coupling discs) always use locking pins and use
whip-check hose safety cables for protection in the event the connection between the
hose and the machine or in between hoses fails.
Ensure not to exceed the maximum pressure specified on the machine.
Never carry pneumatic tools by the hose.
6 AIR SUPPLY
Ensure air valve (or trigger) is in the “off” position before connecting to the air supply.
Item will require air pressure of 90psi, and air flow according to specification.
Drain the air tank daily.
Clean air inlet filter weekly.
Line pressure should be increased to compensate for unusually long air hoses (over
8 meters). The hose diameter should be 3/8 I.D.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make
certain that all connections are secure.
7 LUBRICATION
An automatic in-line filter-regulator-lubricator is recommended (Fig 1) as it increases tool
life and keeps the tool in sustained operation. The in-line lubricator should be regularly
checked and filled with air tool oil.
Proper adjustment of the in-line lubricator is performed by placing a sheet of paper next to
the exhaust ports and holding the throttle open approximately 30 seconds. The lubricator
is properly set when a light stain of oil collects on the paper. Excessive amounts of oil
should be avoided.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWAIR0805 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWAIR0805 in the language / languages: English as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWAIR0805

Powerplus POWAIR0805 User Manual - German - 12 pages

Powerplus POWAIR0805 User Manual - Dutch - 11 pages

Powerplus POWAIR0805 User Manual - French - 11 pages

Powerplus POWAIR0805 Additional guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info