582177
6
Zoom out
Zoom in
Previous page
1/11
Next page
POW902 EN
Copyright © 2014 VARO NV P a g e | 6 www.varo.com
Prior to start-up operation, please be sure to make some preparations:
Make sure the voltage of your power network complies with the voltage listed on the data
plate and that the device is equipped with the correct power plug.
Please make no-loading test before start-up operation at first, and please check:
a, The flexibility of the operating switch (16) to insure the controlling of the hoisting and
lowering of the load hook (12).
b, The flexibility of lift limit bracket (8) to make sure the cut-off of circuit.
c. The flexibility of down limit bracket (9) to make sure the cut-off circuit when the steel
cable (7) is nearly used up.
d, Any abnormal sounds when start-up operation.
e, The steel cable (7) is possible damaged (split or bent), change the cable immediately.
Please check the brake before operating after load.
Please inspect the load hook (12) before operation is possible damaged or distortional,
replace it in time.
Operation using a residual current protective device (Emergency Switch, 15) offers
additional protection.
Please be sure to the enough lubricant on parts. Daub the lubricant on the load hook (12),
cable drum shaft, slow down box, and bearing every half a year.
Please daub the lubricant on the nesting of cable drum shaft when replace the steel cable
(7) every time. Immediately replace the cable if damaged.
Please perform any rework and maintenance tasks only if the power plug is disconnected.
Please inspect the device for transportation damages. Immediately report any possible
damages to your seller.
8 INSTALLATION
Install the cable hoist on a steel beam (Fig 2). Use only the enclosed installation brackets
(1) which can be attached to the top of the mounting casing (3) using the screws, washers
and spring lock washers. The steel beam must be able to withstand at least double the
rated weight of the machine. Contact a professional installer for best results.
The steel beam must have the following dimension: 46 x 46 mm, a wall thickness of at
least 2.3 mm and a length of at least 450 mm (Fig 1).
The steel beam must be securely anchored in a wall. The anchor must be installed
correspondingly sturdy in order to be able to withstand the load.
Please be sure that the machine is installed level and not slanted.
The remote control (14) must be easily accessible at all times and must therefore be
installed at a distance to the floor of between 0.8 m and 1.5 m (Fig 3).
Insert the load hook (12) into the hook bracket (5) of the mounting casing (3) when using
the load hook with pulley (13).
The electric pulley will be attached at the top. Attach the pulley with bearer frame on the
crossbar. The girder is then attached to the support columns. The support columns must
be, in accordance with the requirements of the customer, properly secured on the working
area. The support columns must be installed to be sturdy and stable. Also be able to
withstand a nominal load long-term.
9 OPERATION
Prior to starting work, please be sure that the steel cable (7) is wound up exactly, layer
next to layer on the cable spool (6). Never unwind the cable completely!
Unwind the cable only to the point that at least 3 more layers are located on the drum.
If the red indicator mark is visible, please stop the cable hoist immediately and do not
continue to unwind the cable!
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POW902 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POW902 in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POW902

Powerplus POW902 User Manual - German - 13 pages

Powerplus POW902 User Manual - Dutch - 12 pages

Powerplus POW902 User Manual - French - 13 pages

Powerplus POW902 Additional guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info