628495
45
Zoom out
Zoom in
Previous page
1/105
Next page
ERROR#040
This error occurs as the result of an
AMASGN command. It happens when the command would
remove a microphone from an automixer where it is assigned as the "last mic on" and the
automixer is set to manual "last mic on" mode.
ERROR#041
This error occurs as the result of an
AMASGN command. It happens when the command would
remove a microphone from an automixer where it assigned as the chairman imcrophone and
the automixer has chairman mode enabled.
ERROR#042
This error occurs as the result of an
AMLMM command. It happens when the command
attempts to set "last mic on" mode to manual, but the last mic number is set to a microphone
that does not belong to the specified automixer.
ERROR#043
This error occurs as the result of an
AMLMN command. It happens when the command
attempts to set a "last mic on" number that does not belong to the specified automixer while
"last mic on" mode is set to manual.
ERROR#044
This error occurs as the result of an
AMCHAIR command. It happens when the command tries
to enable chairman mode, but the chairman microphone is set to a microphone that does not
belong to the specified automixer.
ERROR#045
This error occurs as the result of an
AMCHAIR command. It happens when the command tries
to set the chairman microphone to a microphone that does not belong to the specified
automixer while chairman mode is enabled.
ERROR#060
This error occurs when the user has attempted to utilize more variable DSP resources than are
available. This may occur if too many matrix crosspoints are unmuted or too many parametric
EQ filters are enabled. The
DSPLOAD command can query the current percentage utilization of
DSP resources.
ERROR#070
This error occurs as a result of a macro or preset execution command (
PRESETX, PRESETQ,
MACROX, MACROQ). It indicates that the macro or preset requested was empty.
ERROR#071
This error occurs as a result of a
PRESETW or PRESETK command. In the case of PRESETW it
indicates that an attempt was made to write to a factory preset, which is not allowed. In the
case of
PRESETK, it indicates that an attempt was made to delete a factory preset, which is
not allowed.
ERROR#072
This error occurs as a result of a
PRESETQ command. It indicates that one or more commands
in the preset had errors during execution.
ERROR#073
This error occurs as a result of a
MACROA command when there are already too many
commands in the macro. The limit is 256 commands per macro.
ERROR#074
This error occurs in response to a
MACROA or a logic pin (LIA, LIH, etc.) command. If the
command written to the macro or logic pin is illegal, then this error occurs.
ERROR#075
This error occurs when a command attempts to write non-volatile memory, but non-volatile
memory is password protected via
NVLOCK.
ERROR#076
This error occurs when attempting to add a macro command (either during an upload or while
writing a single macro) and the Vortex runs out of room in non-volatile memory. As a result,
the entire macro is discarded. If this occurs during an upload, all previous macros (before the
one that caused the error) are written successfully.
ERROR#077
This error occurs when attempting to add a command to a macro, but the Vortex is not in the
process of writing a macro. This may happen if you forget to do a MACROS or UMACROS
command, or if you had an ERROR#076 and continued trying to add commands.
ERROR#090
This error indicates an EF Bus hardware handshaking error. This could happen if bussed units
are not powered on simultaneously. Powering the units up simultaneously should remove the
error.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polycom Vortex EF2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polycom Vortex EF2280 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polycom Vortex EF2280

Polycom Vortex EF2280 User Manual - English - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info