■ The seal between the hob and the work
surface must be moisture-proof. The work
surface must be absolutely level, as must
the hob of course!
If the work surface is tiled it could be
necessary to use liquid silicone rubber
instead of the sealing strip.
■ If the hob is enclosed between the back
and side panels a minimum distance of
400 mm from these panels should be
observed (Fig. 7).
■ Tighten the mounting clips equally (Fig. 8).
A hob should preferably not be positioned
immediately above a refrigerator or freezer
built-in below the worktop. If the hob has to be
fitted above a refrigerator or freezer, ensure
that the hob is well insulated.
Electrical connection
230 V -50 Hz
■ The appliance should always be earthed.
Use good quality cable for connecting e.g.
H05RRF, 1,5 or 2,5 mm
2
, with 3 or 5 cores,
depending on the regulations.
With following colour code:
brown = phase L
blue = phase N
green/yellow = earth ( )
black= neutral or phase
Depending upon the wiring diagram, you
can use the black cores for neutral or a
phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
To connect the appliance a fixed connection
has to be made. The wire which is coloured
green and yellow must be connected to the
terminal which is marked by the letter E or the
earth symbol or which is coloured green,
or green and yellow. The wire which is
coloured blue must be connected to the
terminal which is marked by the letter N or
which is coloured black. The wire which is
coloured brown must be connected to the
terminal which is marked by the letter L or
which is coloured red. If the input of the
appliance exceeds 3 kW, the appliance has to
be connected to an outlet with a rated current
exceeding 13 Amp.
12
INSTALLATION