731546
26
Zoom out
Zoom in
Previous page
1/36
Next page
© PCE Instruments
23
English
5 Operation
5.1 Measurement
To take a measurement, turn on the device by pressing the “On/Off” key. Once the device gets
to the main screen, it measures the sound level continuously.
To select one of the available measuring ranges, press the “LEVELkey. You can choose
between the following options: Lo (30 … 80 dB), Med (50 … 100 dB), Hi (80 …130 dB), Auto
(automatic measuring range selection).
Make your choice depending on the ambient sound level. If the ambient sound level falls below
the selected measuring range, the display shows “UNDER”. If the ambient sound level exceeds
the selected measuring range, the display shows “OVER”.
To change the frequency weighing of the sound level measurements, press the “A/C” key. You
can switch between A-weighing and C-weighing.
To change the sampling rate, press the “FAST/SLOW” key. You can switch between “FAST” (1
measurement / 125 ms) and “SLOW” (1 measurement / 1 s).
5.2 Further functions
5.2.1 MIN/MAX hold function
You can freeze the maximum and minimum values on the display. To do so, press the
“MAX/MIN” key. Now, a “MAX” indication appears on the display, which means that the
maximum value (since the activation of the function) is shown on the display.
Press the “MAX/MIN” key again to activate the MIN hold mode. Now, the display shows a “MIN”
indication and the minimum value (since activation of the function) is shown on the display.
Press the “MAX/MIN” key again to deactivate the function and to return to normal measuring
mode.
5.2.2 Hold function
You can freeze the current reading on the display at any time by pressing the “HOLD” key. To
unfreeze it, press the “HOLD” key again.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PCE instruments PCE-MSM 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PCE instruments PCE-MSM 4 in the language / languages: English, German as an attachment in your email.

The manual is 1,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info