To activate peak mode, press the soft key
labelled ►. If the meter is already in the peak
function, pressing ► causes the meter to turn
off peak mode.
: Risk of Electrocution. Before use,
always test the voltage detector on a known
live circuit to verify proper operation.
: Insulation type and thickness,
distance from the source, and other factors
may affect operation. Always verify live
voltage using other methods before working
on electrical circuits.
• The non-contact voltage detector operates
when the meter is set to any measuring
function. The detector does not operate
when Auto Power Off turns the meter off or
when the rotary function switch is set to the
off position.
• Slowly move the detector probe closer to the
conductor being tested.
• If AC voltage within the specified range is
present, the indicator light will illuminate.
NOTES: The detector is designed with high
sensitivity. Static electricity and other sources
of electrical energy may randomly activate
the detector. This is normal operation. The
detector only activates the indicator light
when AC voltage is present. It does not
indicate the voltage level on the LCD.