100
GB / IE / NI
coatings, some wood types, minerals and
metal can be harmful to one’s health.
Touching or breathing-in the dust can cause
allergic reactions and/or lead to respiratory
infections of the user or bystanders.
Certain dust, such as oak or beech dust,
is considered carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
- Always use dust extraction.
- Provide for good ventilation of the
working place.
- It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
Prevent dust accumulation at the
workplace.
Dust can easily ignite.
The dust/chip extraction can be blocked by
dust, chips or workpiece fragments.
- Switch the machine off and pull the mains
plug from the socket outlet.
- Wait until the saw blade has come to a
complete stop.
- Determine the cause of the blockage and
correct it.
External Dust Extraction
For dust extraction, a vacuum hose (size
Ø 35 mm) can also be connected to the dust
extraction spout.
- Connect the vacuum hose with the dust
extraction spout .
The vacuum cleaner must be suitable for
the material being worked.
When vacuuming dry dust that is
especially detrimental to health or
carcinogenic, use a special vacuum
cleaner.
The saw is equipped with a sawdust bag (21)
for sawdust and chips.
Squeeze together the metal ring on the dust
bag and attach it to the outlet opening in the
motor area.
The sawdust bag (21) can be emptied by
means of a zipper at the bottom.
8.12 Changing the saw blade
(Fig. 1/17/18/19/20)
Allow the machine head (4) to rise to the
upright position.
Loosen the cover plate screw with the
4 mm Allen key (e).
WARNING!
Do not remove this screw.
Hold the release lever (3) to the right.
Then, rotate the cover plate (20) upward
and raise the movable blade guard to
the upper position to expose the flange
bolt (35). Let the release lever (3) move
back to its default position.
Place the 6 mm Allen key (d) over the
flange bolt.
Press the saw shaft lock (37), holding
it in firmly while turning the 6mm Allen
key (d) clockwise. The shaft lock will be
engage after turning the 6mm Allen key.
Continue to hold the saw shaft lock to
keep it engaged, while turning the blade
Allen key clockwise to loosen the flange
bolt (35).
Remove the flange bolt (35) and the
outer flange (36).
Take the saw blade (6) off the inner
flange (38) and pull out downwards.
NOTE:
Pay attention to the pieces
removed, noting their position and
direction they face.
Carefully clean the flange bolt (35), outer
flange (36) and inner flange (38).
Fit and fasten the new saw blade (6) in
reverse order.
Important!
The cutting angle of the teeth,
in other words the direction of rotation of
the saw blade (6) must coincide with the
direction of the arrow on the housing.
Hold the release lever (3) to the right.
Rotate the cover plate (20) downward
Attachment and operation
105


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PZKS 1500 B2 - IAN 295934 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PZKS 1500 B2 - IAN 295934 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 2,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info