result of stiffness.
7.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch
on the compressor. To switch off the
compressor, press the ON/OFF switch down.
7.7 Adjusting the pressure: (Fig. 1,3).
You adjust the pressure on the pressure
gauge (5) using the pressure regulator (3).
The set pressure can be taken from the
quick-lock coupling (4).
The vessel pressure can be read on the
pressure gauge (6).
The vessel pressure can be taken from the
quick-lock coupling (20).
7.8 Adjusting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7.9 Fitting the compressed air hose
(Fig. 1, 3)
Use the compressed air hose (14) if you intend
to carry out work at a greater distance from the
compressor. To do so, connect the nipple (H)
on the compressed air hose to one of the quick-
release couplings (4, 20). Then attach the
compressed air tool to the quick-release
coupling (G) on the compressed air hose.
8. Replacing the power cable
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer or its after-sales service or
similarly trained personnel to avoid danger.
9. Cleaning, maintenance,
ordering of spare parts and
storage
Important.
Pull the power plug before doing any
cleaning and maintenance work on the
appliance.
Risk of injury by electric shock.
Important.
Wait until the equipment has cooled down
completely. Risk of burns!
Important.
Always depressurize the equipment before
carrying out any cleaning and maintenance
work. Risk of injury.
9.1 Cleaning
Keep the equipment free of dirt and dust as
far as possible. Wipe the equipment with a
clean cloth or blow it down with compressed
air at low pressure.
We recommend that you clean the
equipment immediately after you use it.
Clean the equipment regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the
equipment. Ensure that no water can get
into the interior of the equipment.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
9.2 Maintenance work on the pressure
vessel (Figure 1)
Important. To ensure a long service life of the
pressure vessel (7), drain off the condensed
water by opening the drain plug (9) each time
after using. Release the vessel pressure.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, then
please contact the customer service workshop.
12
GB/
CY
Anleitung_4010362:_ 27.05.2010 13:08 Uhr Seite 12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 270 A1 - IAN 49394 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 270 A1 - IAN 49394 in the language / languages: English, German, Danish as an attachment in your email.

The manual is 3,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PKO 270 A1 - IAN 49394

Parkside PKO 270 A1 - IAN 49394 User Manual - German, Dutch, French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info