5. Technical data
Mains connection: 230 V ~ 50 Hz
Motor rating kW: 1.8 kW
Mode of operation S1
Compressor speed min
-1
: 2850
Operating pressure bar: max. 8
Pressure vessel capacity (in liters): 24
Theoretical suction power l/min.: approx. 270
Sound power level L
WA
in dB: 94
K
WA
uncertainty 4 dB
Protection type: IP20
Weight of the unit in kg: 26,5
Oil (15W 40) 0.3 l
6. Before starting the equipment
Check the equipment for damage which
may have occurred in transit. Report any
damage immediately to the transport
company used to deliver the compressor.
Install the compressor in the vicinity of the
point of consumption.
Avoid long air lines and supply lines
(extension cables).
Make sure that the intake air is dry and
dust-free.
Do not install the compressor in a damp or
wet room.
The compressor may only be used in
suitable rooms (with good ventilation and an
ambient temperature from +5 °C to 40 °C).
There must be no dust, acids, vapors,
explosive gases or inflammable gases in the
room.
The compressor is designed to be used in
dry rooms. It is prohibited to use the
compressor in areas where work is
conducted with sprayed water.
The oil level in the compressor pump has to
be checked before putting the equipment
into operation (see 9.4).
7. Assembly and starting
Important.
Remove the transportation braces
(between the compression pump and
cladding) prior to initial start-up. If the
transportation braces are not removed,
heat can build up and cause the
compressor to ignite.
Important.
You must fully assemble the appliance
before using it for the first time.
You will require the following tools for assembly
and installation:
2 x open-ended wrench size 13 mm (not
included)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting foot (8)
Fit the supplied supporting foot as shown in
Figure 6.
7.3 Fitting the air filter (15)
Remove the transportation stop (B) and screw
the air filter (15) to the equipment. (Fig. 7, 8).
7.4 Changing the transportation cover (A)
Remove the transportation cover from the oil
filler opening (21) and insert the supplied oil
sealing plug (16) into the oil filler opening. (Fig.
9,10).
7.5 Mains connection
The compressor is equipped with a mains
cable with shock-proof plug. This can be
connected to any 230V ~ 50 Hz shock-proof
socket which is protected by a 16 A fuse.
Before you use the machine, make sure that
the mains voltage complies with the
specifications on the rating plate.
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can
impede motor start-up.
In the case of low temperatures below
+5°C, motor start-up is jeopardized as a
11
GB/
CY
Anleitung_4010362:_ 27.05.2010 13:08 Uhr Seite 11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PKO 270 A1 - IAN 49394 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PKO 270 A1 - IAN 49394 in the language / languages: English, German, Danish as an attachment in your email.

The manual is 3,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside PKO 270 A1 - IAN 49394

Parkside PKO 270 A1 - IAN 49394 User Manual - German, Dutch, French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info