Introduction / Safety Information
Safety Information
J IMPORTANT! Danger of poisoning.
Emissions, fuels and lubricants are
toxic. Do not inhale emissions.
J Children are to be kept away from
the generator.
J IMPORTANT! Risk of burns. Do
not touch the exhaust system or drive
unit. Please observe the warning
notes depicted on the generator.
J Wear suitable ear protection when in the vicinity
of the equipment.
J IMPORTANT! Petrol and petrol
fumes are highly combustible or
explosive.
J Never operate the generator in non-
ventilated rooms or in a highly inflam-
mable environment. If you intend to
operate the generator in rooms with good ven-
tilation, the exhaust gases must be channeled
directly outdoors through an exhaust hose.
IMPORTANT! Toxic exhaust gases
can escape despite the exhaust hose.
Due to the fire hazard, never direct
the exhaust hose towards inflammable materials.
J RISK OF EXPLOSION! Never
operate the generator in rooms with
combustible materials.
J The speed preset by the manufacturer is not
allowed to be changed. The generator or con-
nected equipment may be damaged.
J Secure the generator against shifting and top-
pling during transport.
J Place the generator at least 1m away from walls
and equipment connected to them.
J Place the generator in a secure, level position.
Do not turn, tip or change the generator’s posi-
tion while it is working.
J Always switch off the engine when transporting
and refueling the generator.
J Make sure that when you refuel the generator
no fuel is spilt on the engine or exhaust pipe.
J Never operate the generator in rain or snow.
J Never touch the generator with wet hands.
J Guard against electric danger.
J When working outdoors, use only extension
cables that are approved for outdoor use and
which are marked accordingly (H07RN).
J The overall length of the extension cables used
is not allowed to exceed 50 m for 1.5 mm²
and 100 m for 2.5 mm².
J No changes may be made to the settings of
the motor or generator.
J Installation, repair and maintenance work must
only be performed by authorised qualified
personnel.
J Do not refuel or empty the tank near open
lights, fire or sparks. Do not smoke!
J Do not touch any mechanically driven or hot
parts. Do not remove the safety guards.
J Do not expose the equipment to damp or dust.
Permissible ambient temperature
-10 to +40°,
altitude:
1000 m above sea level,
relative humidity:
90 % (non-condensing)
J Generators may only be stressed up to the limit
of the nominal load under the given operating
conditions. If the generator is used under con-
ditions that differ from the ones stated above,
and motor or generator cooling is impaired,
e.g. as a result of operation in small rooms, the
load must be reduced. A reduction in the load
must be made at higher temperatures, altitude
and humidity, compared with that stated in the
operating conditions.
J The generator is driven by a combustion engine,
which produces heat in the range of the exhaust
(on the opposite side of the socket) and exhaust
outlet. You should therefore avoid coming near
these surfaces because of risk of skin burns.
J The values quoted in the technical data under
sound power level (LWA) and sound pressure
level (LpA) are emission values and not neces-
sarily reliable workplace values. As there is a
correlation between emission and immission
levels, the values cannot be taken to reliably
determine the possible need for additional pre-
cautions. Factors influencing the current immis-
sion level of the user / operator include the
properties of the work area, other sound
sources etc., e.g. the number of machines and
other neighboring processes, and the time
span over which the user / operator is subjected
to the noise. Also, the permitted immission level
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 85052 PSE 2800 B2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 85052 PSE 2800 B2 in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 2,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Parkside IAN 85052 PSE 2800 B2

Parkside IAN 85052 PSE 2800 B2 User Manual - French - 41 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info