General safety instructions for air tools / General safety rulesGeneral safety instructions for air tools
control the compressed air unit in unforeseen
circumstances.
Do not use any device if its switch is defective.
A device that can no longer be switched on and
off is dangerous and must be repaired.
Store the device out of the reach of children
when it is not in use. Do not let anyone use the
device if he or she is not familiar with it or has
n
ot read the instructions and advice. Compre
ssed
air units are dangerous when they are used by
inexperienced people.
Maintain the device carefully. Check that mov-
ing device parts are working properly and move
freely. Check for any parts that are broken or
damaged enough to detrimentally affect the
functioning of the device. Have damaged parts
repaired before using the device. Many acci-
dents have their origins in poorly maintained
devices.
Switch the device off if you do not use it anymore.
Always wear personal protective
equipment and safety glasses. Wear-
ing personal protective equipment
such as dust mask, non-slip safety shoes, safety
helmet or ear protectors, depending on the
type of air tool and its application, reduces the
risk of injuries.
Check the connections and supply lines. All
maintenance devices, couplings and hoses must
be equipped to meet the pressure and air amounts
specified in the device specific values. Pressure
that is too low influences the functioning of the
device; pressure that is too high can cause dam-
age to property and personal injury.
Protect hoses from kinks, constrictions, solvents
and sharp edges. Keep hoses away from heat,
oil and rotating parts.
Make sure that the hose clamps are always
tightly fastened. If the hose clamps are not tightly
fastened or are damaged, the air could escape
uncontrollably.
Replace damaged hoses immediately. A dam-
aged supply line may result in the air hose
flapping about and may result in injuries.
If the power cable of the appliance is damaged,
it has to be replaced by the manufacturer or its
service department or a similarly qualified per-
son in order to avoid hazards.
Do not use the device when tired or under the
influence of drugs, alcohol or medications. One
moment of carelessness when using the device
may result in serious injuries.
Do not directly inhale the exhaust air. Keep ex-
haust air away from the eyes. Exhaust air from
the air tool may contain water, oil, metal particles
or contaminants from inside the compressor. This
may damage your health.
CAREFUL WHEN PUT-
TING THE TOOL DOWN! Always put down
the device so it does not come into contact with
the trigger. This could potentially result in acci-
dental activation of the device, which again
could result in hazards.
Only use suitable accessories. These may be
purchased from the manufacturer. Using non-OE
M
accessories may result in hazards.
Only use filtered and regulated compressed air.
Dust, caustic vapours and / or moisture may dam-
age the motor of the compressed air tool.
The hose must be designed for pres-
sures of at least 8.6 bar or 125 PSI,
but at least 150 % of the maximum
pressure generated in the system.
The tool and supply line must be
equipped with a hose coupling to
completely release pressure when
disconnecting the coupling hose.
DANGER! Avoid contact with live lines. This
device is not insulated against electric shock.
RISK OF INJURY! High
working pressures can give rise to recoil forces
t
hat under certain conditions can result in dang
er
from continuous loading.
If you are inexperienced in the use of this type
of device, you should seek training on how to
handle it safely.
DANGER OF STAB
W
OUNDS! Do not treat an injection as a simpl
e
cut. A high pressure jet may inject toxins into the
body and cause serious injuries. If the spray is
injected into the skin, seek medical help imme-
diately.
Do not modify this device in any way without the
manufacturer‘s approval.
Only use the compressed air unit with the spec-
ified pressure (6.3 bar).
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 275685 PDMH 4500 A3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 275685 PDMH 4500 A3 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info