Commissioning / After initial use / Maintenance
Adjusting the compressed air
Note: this device is designed for an operating
pressure of up to 6.8 bar and a compressor with
the minimum air flow specified in the technical spe-
cifications. When setting the air pressure, remem-
ber the pressure drops by approx. 0.6 bar with a
hose length of 10 m and an inner diameter of
9 mm.
Only use filtered, lubricated and regulated
compressed air.
Initial use
Activate the On / Off switch
3
to start using
the device.
Release the On/ Off switch
3
to switch the
device off.
Changing rotation
ATTENTION! The device must come to a
complete standstill before changing the direc-
tion of rotation.
ATTENTION! A machine rotating in an unex-
pected direction can be dangerous. Always
pay attention and use care.
Note: The power drill is designed for clock-
wise/counter-clockwise rotation. Use the
forward/reverse switch
4
to change the
direction of rotation of the power drill.
Set the forward/reverse switch
4
to position F
to switch to clockwise rotation.
Set the forward/reverse switch
4
to position R
to switch to counter-clockwise mode.
After initial use
Once the task has been finished the device must be
disconnect from the compressed air supply
5
.
Briefly activate the On / Off switch
3
on the
device to bleed any residual compressed air.
Now pull back the safety on the connection
coupling of your compressed air hose.
Now remove the hose from the plug nipple
8
.
Careful when putting the device
down. Always put down the device so it does
not rest on the trigger. This could potentially re-
sult in inadvertent activation of the tool, which
in turn could result in hazards.
Maintenance
ATTENTION! All maintenance must be per-
formed by trained individuals. Follow the specified
maintenance instructions to ensure a long life and
proper operation of this quality product.
Disconnect equipment from the compressed air
source when performing maintenance and care.
Check the condition of wear and tear items
and accessories with each maintenance.
Note: Daily cleaning and regular lubrication
are an absolute necessity for smooth operation.
Only use special tool oil with a high viscosity
(thin fluid). Oil for compressed air tools or
SAE10-20 motor oil are suitable.
ATTENTION! Do not use other (especially
high viscosity) lubricants. Malfunctions or per-
manent damage may otherwise occur.
The following lubricating options are
available:
a) via oil-mist generator
To use the oil-mist generator plug the plug
nipple
8
directly into the equipment and con-
nect with your air hose.
b) by hand
Alternatively you can also manually lubricate
your equipment (not recommended).
To do so, remove the screw plug on the oil filler
port.
Apply 3–5 drops of oil to the compressed air
connection before using the compressed air
tool
4
.
If the air tool has not been used for several
days 5–10 drops of oil must be added to the
air connection
5
.
... / Cleaning and Care / Information about warranty and service processing
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 275685 PDBS 2200 A2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 275685 PDBS 2200 A2 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 1,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info