745335
11
Zoom out
Zoom in
Previous page
1/102
Next page
11
IE
GB
In this mode (low pressure), the unit will
automatically draw in cleaning agent from
the built-in tank (cf. “Using detergents”).
Push in the tip of the nozzle to change to
high-pressure operation.
B
Lock / unlock the starting lever
(25) of the gun (1) by depressing
the locking knob (24).
Lock the starting lever (25) to
prevent the pressure cleaner
from being inadvertently / ac-
cidentally started.
Locked
Open
Interrupting operation
Release the lever of the gun (1).
During prolonged work intervals turn
off the pressure cleaner by its ON /
OFF switch (10).
If the equipment falls over,
switch off the equipment
immediately at the on/off
switch (6) and disconnect the
equipment from the mains at
the mains power cord. Risk
of electric shock! Only now
should the equipment be re-
turned to an upright position.
For your own safety, wait
approx. 5 minutes before re-
connecting to the electricity.
Ending operation
1. After having worked with a detergent
rinse the pressure cleaner with clear
water.
2. Release the lever of the gun (1).
3. Turn off the pressure by its ON / OFF
switch (6). Disconnect the mains plug.
4. Turn off the water tap.
5. Disconnect the pressure cleaner from
the water mains.
6. Pull the lever of the gun (1) to vent the
pressure existing within the system.
Using detergents
The pressure cleaner was designed for
operation with a neutral detergent based
on a biologically decomposable anionic
tenside. Other detergents or chemical sub-
stances could impair the safety of the pres-
sure cleaner and damage it. Such damage
to the equipment is not covered by the
guarantee.
Fill/drain detergent:
To add cleaning agent to the jet, you
must rst ll the cleaning agent tank
(17).
To remove the cleaning agent tank
(17), hold it on the side and push it up-
wards. You can now pull the cleaning
agent tank out of the bottom and side
guides on the pressure cleaner. Mind
to rst remove the induction hose and
the cap from the opening of the clean-
ing agent tank (16) as they will remain
on the pressure cleaner.
To reinstall the cleaning agent tank
(17), trace back the above steps.
Working Instructions:
Operate the standard Vario nozzle
(19) in low-pressure mode to automati-
cally add cleaning agent to the water.
The rotating wash brush (20) is always
in low-pressure mode and cleaning
agent will thus always be added to the
water.
If you want to use the rotating wash
brush (20) without cleaning agents, the
cleaning agent tank (17) suction hose
must be placed in an empty cleaning
agent tank or leading outside.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside IAN 270433 PHD 150 D3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside IAN 270433 PHD 150 D3 in the language / languages: English, German, Dutch, Danish, French, Swedish as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info