4 Operation
4-20 FrameSaver NP 110 Users Manual - Installation Guide 980-001-0240B
November
2000
4. Desired Loss Mon Rate - Setting for the rate at which a Loss measurement
packet (Packet-Counting packet) is injected on each PVC in the list specified at
the bottom of this screen. Default value (60) dictates that within each 60-second
period, every PVC in the list is measured once. A PVCs packet is considered lost
if it does not return before a subsequent packet is injected on that PVC. On a per-
PVC basis, the originating unit delays 10 seconds if the previous response was
lost. The packet send rate cannot exceed 10 per second.
NOTE: FrameSaver NP 110 Loss packets are 42 bytes in length, when issued. A
FrameSaver NP looping (receiving and returning) a Loss packet will add two
additional bytes to the packet.
5. Drpd Mon Pkt Thres - FrameSaver NP 110 maintains a count of monitor
packets lost (both Delay and Loss packets) for the current interval for each PVC.
When either of the monitor packet counts on any PVC equals or exceeds this
threshold setting, a PVC Drpd Mon Alarm is declared. The alarm is cleared
when all PVCs in a subsequent interval fail to equal or exceed the threshold
value. Applies to auto and manually learned DLCIs.
6. PVC Delay Thres - FrameSaver NP 110 maintains an average delay
measurement for each PVC for the current interval. A PVC Delay Alarm is
declared when the average on any PVC equals or exceeds this setting. The alarm
is cleared when all PVCs in a subsequent interval fail to equal or exceed the
threshold value. Applies to auto and manually learned DLCIs.
7. PVC Dlvd Pkt Thres - A PVC Dlvd Pkt Alarm is declared when the
percentage of packets delivered on any monitored PVC falls below this threshold
setting. The alarm is cleared when all PVCs in a subsequent interval fail to fall
below the threshold value. Applies to auto and manually learned DLCIs.
8. Interval Period - Sets the time period for each interval of PVC statistics,
from one (1) to 15 minutes.
NOTE: Changing the interval period will cause all PVC and Protocol Monitoring
statistics to be cleared.
9. LMI CIR Values - Selecting Use, sets (automatically) the CIR value of each
PVC to the value reported by the Frame Switch LMI message.
NOTE: This feature operates only with LMI LMI Protocol selected.
10. CIR Bins - Sets the upper value (in %) for each of the six bins in which CIR
data will be collected. All six values must be entered with each setting.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paradyne FrameSaver NP 110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paradyne FrameSaver NP 110 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info