Chapter 5Maintenance — Lamp/temperature/lter indicators
142 - ENGLISH
Temperature indicator <TEMP>
Indicator status Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status Warm-up status
Internal temperature is high
(warning).
Internal temperature is high
(standby status).
The cooling fan has
stopped.
Cause
f Did you turn on the power
when the temperature
was low (around 0 °C
(32 °F))?
f Is the air intake/exhaust port blocked?
f Is the room temperature high?
f Is the lter indicator <FILTER> lit?
Solution
f Wait up to 20 minutes in
the current status.
f Install the projector in a
location with the operating
environment temperature
between 0 °C (32 °F) and
45 °C (113 °F)
*1
.
f Remove any objects that are blocking the air intake/
exhaust port.
f Install the projector in a location with the operating
environment temperature between 0 °C (32 °F) and
45 °C (113 °F)
*1
, and ambient humidity between 20 %
and 80 % (no condensation).
f Do not use the projector at high altitudes of 2 700 m
(8 858') or higher above sea level.
f Clean or replace the air lter unit. (x page 143)
f Turn the <MAIN POWER>
switch to <OFF>
(x page 50), and
consult your dealer.
*1 When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level), the operating environment temperature
should be between 0 °C (32 °F) and 40 °C (104 °F).
If you use the smoke cut lter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be
used at high altitudes.
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Filter indicator <FILTER>
Indicator status Lighting in red Blinking in red
Status
The lter is clogged.
The temperature inside or outside the projector is abnormally high.
The air lter unit is not
attached.
Cause f Is the air lter unit dirty?
f Is the air intake/exhaust
port blocked?
f Is [HIGH ALTITUDE
MODE] set correctly?
f Is the air lter unit
attached?
Solution
f Clean or replace the air
lter unit. (x page 143)
f Remove any objects that
are blocking the air intake/
exhaust port.
f When using the projector
at high altitudes between
1 400 m (4 593') and
2 700 m (8 858'), set
[HIGH ALTITUDE MODE]
(x page 96) to [ON].
f Do not use the projector
at high altitudes of
2 700 m (8 858') or higher
above sea level.
f Attach the air lter unit.
Note
f If the lter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.
f If the lter is clogged while [LAMP SELECT] is set to [QUAD] or [TRIPLE], the setting may be forcibly changed to [DUAL]. To reset the
setting, clean the air lter unit or replace it with a new one.
142


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic PT-DZ16KU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic PT-DZ16KU in the language / languages: English as an attachment in your email.

The manual is 19,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info