"Primary DNS Server
" and "Secondary
DNS Server" can be entered only if "DNS
Server" is set to "Manual".
If the value for "Primary DNS Server" or
"Secondary DNS Server" contains 1 or 2
digits numbers, enter these numbers as
they are. Do not enter like [.001].
Example: The IP address is [192.168.0.1].
Correct entry: [192.168.0.1]
Wrong entry: [192.168.000.001]
"SIP Server": Use [
][ ] to select "ON" or
"OFF" (default).
"ON": You can communicate using a SIP
server.
"OFF": You cannot communicate using a SIP
server.
Note
If
SIP settings have not been configured on
the SIP settings screen, you cannot select
"ON" (Page 116). For details, contact your
network administrator.
To select "ON", "Gatekeeper" must be set
to "OFF".
If video conference calls cannot be made
because there is a problem with the SIP
server, the SIP settings are incorrect (on the
server, or on the unit), etc., "Not
registered" will be displayed on the Home
screen instead of the SIP user name. In this
case, you cannot make calls using either IP
addresses or SIP. Contact your network
administrator.
"SIP Transport Protocol": Press [Enter] and then
use [
][ ] to select between protocols (UDP,
TCP, "Auto (Switch by Site)", or "Auto (TCP /
UDP)"
[default]) used when communicating via SIP.
Note
When "Auto
(Switch by Site)" is selected,
TCP will be used if using a SIP server, and
UDP will be used if not using a SIP server.
When "Auto (TCP / UDP)" is selected,
communication will be attempted in order of
TCP and then UDP. Normally, select "Auto
(TCP / UDP)".
"Gatekeeper": Use [
][ ] to select "ON" or
"OFF" (default).
Note
To select "ON", "SIP Server" must be set
to "OFF".
"ON" cannot be selected unless the
gatekeeper
settings have been made on the
H.323 settings screen (Page 118). For
details, contact your network administrator.
If video conference calls cannot be made
because there is a problem with the
gatekeeper and H.460 server, the H.323
settings are incorrect (on the gatekeeper
and the H.460 server, or on the unit), etc.,
"Not registered" will be displayed on the
Home screen instead of the H.323
extension/H.323 name. In this case, you
cannot make calls using either IP
addresses or the gatekeeper and H.460
server. Contact your network administrator.
"H.460": Use [
][ ] to select "ON" or
"OFF" (default).
Note
To
select "ON", "Gatekeeper" must be set
to "ON" and "Static NAT" must be set to
"OFF".
"ON" cannot be selected unless the
gatekeeper settings have been made on the
H.323 settings screen (Page 118). For
details, contact your network administrator.
"Static NAT": Use [
][ ] to select "ON" or
"OFF" (default).
Note
To select "ON", "IP Address" must be set
to "Manual" and "H.460" must be set to
"OFF".
"ON" cannot be selected unless the WAN
IP
address of the router has been set on the
static NAT settings screen (Page 119). For
details, contact your network administrator.
"Default Call Type": Use [
][ ] to select
"SIP" (default) or "H.323".
Note
These settings can only be made in IP mode
(Page 131).
The default setting is the setting selected as
the "Default Call Type" on the default call
type setting screen (Page 115).
5. Press [G].
A dialogue box to confirm the saving of settings
is displayed.
134 User Manual Document Version 2013-09
Contacts and Settings
134


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Panasonic KX-VC300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Panasonic KX-VC300 in the language / languages: English as an attachment in your email.

The manual is 3,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info